USER MANUAL 

Prepared

 

by

   

 

Reviewed

 

by

 

 

Approved

 

by

 

 

 

 

© 2019 GS Teletech Inc. All rights reserved 

 

 

 
 
 
 
 
 
 
 

GST-IC-ELITE-TNR 

(outdoor) 

 

USER MANUAL 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

  GS Teletech Inc. 

 
 
 

Summary of Contents for GST-IC-ELITE-TNR

Page 1: ...Version 1 1 Date January 28th 2019 Page 1 47 Title USER MANUAL Prepared by Reviewed by Approved by 2019 GS Teletech Inc All rights reserved 1 GST IC ELITE TNR outdoor USER MANUAL GS Teletech Inc...

Page 2: ...USER MANUAL Prepared by Reviewed by Approved by 2019 GS Teletech Inc All rights reserved 2 CHANGE RECORD DATE NAMES DESCRIPTIONS VERSION REMARK January 10th 2019 Y J KIM Original Draft 1 0 January 28...

Page 3: ...Main Features 9 3 SYSTEM DESIGN 10 3 1 Perspective View 10 3 2 Exterior View 11 3 3 Interior View Outdoor 12 3 4 External Interface Indoor Outdoor 13 4 SYSTEM SPECIFICATION 14 4 1 RF Performance 14 4...

Page 4: ...figuration 27 7 5 Communication Configuration 28 7 6 User Management 29 7 7 Alarm Log 30 7 8 Log 31 7 9 Troubleshooting 32 7 10 Software Update 33 7 11 System Reset 34 7 12 Factory Default Setting 35...

Page 5: ...Configurations 27 Figure 23 System Information for connecting configurations 28 Figure 24 System Information about User Management 29 Figure 25 The way to check System Alarm Log 30 Figure 26 The way t...

Page 6: ...ble 7 GST IC ELITE TNR Operation Band for NR Band N41 16 Table 8 GST IC ELITE TNR Mechanical Environment conditions 17 Table 10 GST IC ELITE TNR RF Signal Flow Outdoor 18 Table 11 GST IC ELITE TNR Dat...

Page 7: ...General 1 1 Purpose This document introduces features specifications structures and operation guideline for the GST IC ELITE TNR LTE NR 1 2 Copyright All text and image in this document are subject to...

Page 8: ...age and capacity of LTE Band 41 and NR Band N41 services in all shadowed and blanked areas of Sprint network GST IC ELITE TNR receives and improves weak signals as cancelling the multi path interferen...

Page 9: ...t Downlink using PIMD Reduction Technology Excellent RF Specifications High Gain more than 95dB Low Noise figure under all system gain condition Less than 5dB Grate Performance of Interference Cancell...

Page 10: ...Title USER MANUAL Prepared by Reviewed by Approved by 2019 GS Teletech Inc All rights reserved 10 3 System Design 3 1 Perspective View Fan may be used as an option if A is installed in an enclosed spa...

Page 11: ...ersion 1 1 Date January 28th 2019 Page 11 47 Title USER MANUAL Prepared by Reviewed by Approved by 2019 GS Teletech Inc All rights reserved 11 3 2 Exterior View Figure 3 GST IC ELITE TNR Exterior View...

Page 12: ...r Amplifier for NR For generating Downlink High RF Power 6 Power Amplifier for LTE NR For generating Uplink High RF Power 7 DFM Digital Filter Module Contains RF Up Down Convertor Digital Signal Proce...

Page 13: ...ort MS22 2 3P 2 RJ 45 Local Maintenance or communication other equipment of GST Local RJ 45 3 RET Remote Antenna Control Port AISG 2 0 SU20SPR 8S 29V_1 5A max 4 FAN FAN Power Alarm Connection MS20 15...

Page 14: ...nnel Capacity BW 20MHz Contiguous 3CH LTE BW60MHz NR Gain Range 65dB 95dB Max 30dB ALC 30dB Adjust Step 0 5dB Accuracy 1dB Ripple 6dB p p each CH Roll off 50dBc Channel OBW 1MHz LTE 30dBc Channel OBW...

Page 15: ...R ICS General Performance 4 3 CH Capacity Information 4 3 1 LTE Band 41 Maximum configurable channel is contiguous 3channel CH Name Channel Frequency BW MHz EARFCN Start MHz Center MHz Stop MHz L01 25...

Page 16: ...2 3 2631 3 18 40913 L33 2633 1 2642 1 2651 1 18 41111 L34 2652 9 2661 9 2670 9 18 41309 L37 2616 8 2625 8 2634 8 18 40942 L38 2636 6 2645 6 2654 6 18 41146 L39 2656 4 2665 4 2674 4 18 41344 L53 2631 4...

Page 17: ...20 15 7P RET SU20SPR Size 22 x 14 1 x 8 6 560mm x 360mm x 220mm Without Bracket Weigh Less than 30kg 66lb Without Bracket Power Consumption Less than 360W MTBF 100 000 hours or higher Internal Modem L...

Page 18: ...NR RF Signal Flow Outdoor Table 8 GST IC ELITE TNR RF Signal Flow Outdoor No RF Signal Flow No RF Signal Flow 1 DL Input UL Output 8 DL Output UL Input 2 Donor Switch DL RF Module 9 Service Switch UL...

Page 19: ...ignal Flow Figure 7 GST IC ELITE TNR Signal and Data Flow Table 9 GST IC ELITE TNR Data Signal Flow No Data signal Flow No Data signal Flow 1 LTE DL AMP DFM LvTTL 6 Donor Switch Control DFM 2 NR DL AM...

Page 20: ...0 GST IC ELITE TNR Power Supply Flow No Power Flow No Power Flow 1 AC 110V Input for SMPS 8 Supply 24V for FAN 2 Supply 29V for LTE DL AMP 9 Supply 6V for Donor Switch 3 Supply 29V for NR DL AMP 10 Su...

Page 21: ...he attenuation value Isolation Unit dB Display the isolation value between Donor antenna and Service antenna Band Selection Select the band that user want to operate Final AMP Set the High Power final...

Page 22: ...Table 11 GST IC ELITE TNR Status Monitoring and Control Parameters 6 2 Alarm Monitoring All of alarms in Repeater are able to check thru Local Maintenance Port Remote Site Provide to Alarm Mask functi...

Page 23: ...P Output Power DSP Output Power 20dB over 30sec Power AMP Gain OK DL Low Isolation Isolation 70dB Opposite Condition UL Low Isolation Isolation 70dB Opposite Condition UL Over Output Output power Exce...

Page 24: ...ll be addressable via the LTE CDMA wireless modem Support Remote access that will enable troubleshooting down to a specific location 7 1 Configuration the Laptop to Connect to the Repeater Connect an...

Page 25: ...eb UI Screen for Log In After Logging User can be able to operate Web UI Register Delete a User name Password Refer to 8 6 User Management Display Total Alarm Shutdown Status Enter the IP Address 192...

Page 26: ...9 Page 26 47 Title USER MANUAL Prepared by Reviewed by Approved by 2019 GS Teletech Inc All rights reserved 26 7 3 RF Status Control Web UI Screen for display Repeater s RF Status Control window Figur...

Page 27: ...by 2019 GS Teletech Inc All rights reserved 27 7 4 Alarm Configuration Web UI Screen for Alarm Configurations Decide to activate an each alarm When Report Alarm is OFF all alarms are disabled When Rep...

Page 28: ...ation Configurations Set the information in order to connect to Sprint Server On this page you can change the various values related to IP network Because the Web UI is based on the IP network incorre...

Page 29: ...r information On this page you can create and delete users change passwords and assign authorities to individual users Read Authority will only allow the user to view information on the menu pages but...

Page 30: ...f reported and reset Alarms When an alarm is reported the name and time of the alarm is displayed along with its current status Red means the alarm is reported Green means the alarm has returned to no...

Page 31: ...itle USER MANUAL Prepared by Reviewed by Approved by 2019 GS Teletech Inc All rights reserved 31 7 8 Log Web UI Screen for reading a List of operation history Logs will maintain a history of up to 30...

Page 32: ...d by Reviewed by Approved by 2019 GS Teletech Inc All rights reserved 32 7 9 Troubleshooting Web UI Screen for informing a contact information in case of occurring Field Troubleshooting Figure 17 The...

Page 33: ...re Upgrade link 2 Click Browse button to select the upgrade file from the laptop 3 Choose the file to upgrade Provided by manufacturer After you choose the file You should click upload to send the fil...

Page 34: ...ved by 2019 GS Teletech Inc All rights reserved 34 7 11 System Reset Web UI Screen for resetting the system Click on the desired reset action Clink Yes to reset the repeater via a soft boot This will...

Page 35: ...Title USER MANUAL Prepared by Reviewed by Approved by 2019 GS Teletech Inc All rights reserved 35 7 12 Factory Default Setting Web UI Screen for Default Setting before operating Figure 20 The way to...

Page 36: ...Prepared by Reviewed by Approved by 2019 GS Teletech Inc All rights reserved 36 7 13 Configuration Transfer Web UI Screen for mutual information transfer between Repeater and Local Craft Figure 21 Th...

Page 37: ...p as below More detailed information about installation refer to the MOP Manufacturer Operating Process Contents Picture Q ty 1 Mounting Bracket wall mount 1EA 2 AC Power Cable SJT AWG 6ft 1EA 3 Insta...

Page 38: ...ck and may cause severe injury Operating the Repeater with antennas in very close proximity facing each other could lead to severe damage to the repeater 8 1 2 Exposure to RF Working with the repeater...

Page 39: ...he cabling diagram of the GST IC ELITE TNR Indoor is as follows Figure 22 GST IC ELITE TNR Outdoor Cabling Diagram From To Cable GST IC ELITE TNR MGB Frame Ground Cable AWG 6 6ft Circuit Breaker Box A...

Page 40: ...device if necessary Circuit Breaker Installation in the Box for Overcurrent Protection Must install the circuit breaker between the system and main AC source for separating Make sure to install the C...

Page 41: ...Prepared by Reviewed by Approved by 2019 GS Teletech Inc All rights reserved 41 8 3 Installation Guide for Crew 8 3 1 Wall Mount Installation The procedure for fixing the wall type system is as follow...

Page 42: ...eviewed by Approved by 2019 GS Teletech Inc All rights reserved 42 2 To mount the system on the wall first fix the bracket on the wanted position Figure 24 Fixing the Bracket for installing a Wall Mou...

Page 43: ...etech Inc All rights reserved 43 3 Hang the system to the hooking position at the top of the mounting bracket Figure 25 The way to hang the system for Wall Mounting 4 Align the system with the fixing...

Page 44: ...AC Port is below User should connect exact polarity of AC Port Outlook Fixed Side Port numbering NAME Description MS 3102A 10SL 3P A AC_H AC Hot B AC_N AC Neutral C F G Frame Ground Table 15 AC Power...

Page 45: ...Fixed Side Port numbering NAME Description SU20SPR 8S 3 RS485B Communication 4 DGND Frame Ground 5 RS485A Communication 6 29 V 1 5A max 7 DC Return Retune DC Power 1 2 8 NC Table 17 GST IC ELIT TNR R...

Page 46: ...by Reviewed by Approved by 2019 GS Teletech Inc All rights reserved 46 8 4 5 Grounding cable Connection JOCT 0202 RL05 Lug supports AWG 6 The way to install the grounding cable is below Figure 28 The...

Page 47: ...the interference at his own expense FCC Part 15 21 statement Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this...

Page 48: ...ct point Charles You chyu gsteletechinc com Office 1 913 469 6699 Fax 1 913 661 0163 FCC Compliance Statement e g products subject to Part 15 This device complies with Part 15 of the FCC Rules Operati...