Main AC fuse is located on the
back plate.
Replace only with same value
fuses. Be very carefull when
replacing fuses not to drop fuse
inside amplifier.
WARNING
Do not remove cover of amplifier
unless AC cords are removed
from amplifier.
TROUBLE
SHOOTING
No Light in Gryphon Logo
*Check both AC cords
*Check both on/off switches on
back panel
*Check your domestic AC supply
*Check AC fuses on rear panel
*Check fuse No.4 under topplate
( 200 mAT )
Logo Light
is on but amplifi-
er will not start up.
*Check error indicators on dis-
play
Error and Fuse
indicator is
flashing.
*Check Fuse no. 3 under top-
plate. ( Remove AC cords first )
Error and Low Powe
r
indi-
cators are flashing.
*Available AC power is to low.
Minimum requirement is:
100 - 120v. Countries : 95 v.
200 - 240v. Countries : 190 v.
Error and Temp. L
indica-
tors are flashing:
Left channel is overheating. Turn
off amplifier and secure air circu-
lation around the unit. Start
amplifier again after 5 min.
Error and Temp R
.
indica-
tors are flashing:
*As above
AC Phase
is on constantly.
*Polarity on the 2 AC cords is
assymetrical. Tutn off amplifier
and reverse 1 of them. ( you may
wish to experiment to find the
ultimate symmetrical configura-
tion. )
Tweak Alert
In the best Gryphon tradition we
have spent a huge amount of
time with our prototypes before
we release a new product. We
are obsessed with what we do
and consider ourselves to be
open minded and are fascinated
by the "Grey area" between logi-
cal, technical facts and things we
just hear that make no obvious
technical sense, we will imple-
ment it as long as it does not
sacrifice safety or reliability. In
the Antileon design a number of
tweaks can be found and the
result is a fine balance that can
19