4.2 AVAILABLE REMOTE FUNCTIONS
AIR STOVE
(*) = Message recognized:
Ignition, Working, Cleaning, Shutting down, OFF, Alarm.
(**) = See “
SPECIFIC SCENARIOS
”.
Operation to be carried out
SMS to send
Return SMS
Errors SMS
Setting the language.
ENG = English
SET
ENG
Settings done
-
Set the stove type
SETMODE
AIR
Set AIR
-
Light the stove. The stove is lit with temperature and
flame level settings previously given by the user.
ON
Ignition
Error. Stove not
burning. Try again
Stove previously on
Shut down the stove
OFF
Shutting down
Error. Stove not shut
down. Try again (**)
Set the flame level (from 1 to 5 according to the
model).
Y = value to be set
SETPOWER
Y
Power setted
Power level not
correct. Try again
Set the room temperature (from +7°C to +30°C
according to the model).
X = value to be set
SETROOMTEMP
X
Room
temperature set
Room temperature
not correct.
Try again
To know the operating status (
as indicated for
example in bold
).
STATUS
Working
(*)
Room Temp. =
28
Smoke Temp. =
118
Power level =
2
Set Room temp. =
22
-
Upon sending the message HELP there is a return
message with the list of the commands that can
be used for remote-controlled operation of the
stove.
HELP
MESSAGES
RECOGNIZED: ON,
OFF, SET, SETPOWER,
SETROOMTEMP,
STATUS, SETMODE
SETTELNUMBER
HELP, VERSSW
-
For wathever alarm are indicated on the main
telephone as well as data regarding the settings.
(
as indicated for example in bold
).
Refer to the “
USE AND MAINTENANCE
” booklet
for the procedures to be carried out.
-
Alarm
Room Temp. =
22
Smoke Temp. =
140
Power level =
4
Set Room temp. =
20
-
Software version in use
VERSSW
-
-
Operation denied
-
-
Error. Not correctly
setted. Try again
Serial cable disconnected
-
-
Error comunication
between stove and
GPRS-Module
Sending of a SMS with text non included on the
list of the commands.
-
-
Message not
recognized
Change telephone numbers.
0123456789 = main phone number
SETTELNUMBER
+390123456789
Settings done
Error. Failure phone
number entry.
Try again