E 10210 12 - 2005
Protocols:
MODULAR X6 CCTALK VALIDATOR 66
The value of the default classification path is stored in the Flash memory of the Validator.
The values that [Data 1] should take are one of the following:
1: path 1
2: path 2
3: path 3
4: path 4
5: path 5
The value is initially set to path 1.
Command protected by a PIN.
Notes:
a)
A NACK is returned if:
-
The Exit module does not have its software correctly loaded
-
The classification path has an incorrect value: it is not any of the values previously
described.
-
There has been an error in programming the value of the default path in the Flash
memory of the Validator.
b) The Validator does not answer if it is programmed in “L66 compatibility” mode.
Example:
Send:
[2] [1] [1] [189] [3] [60]
Reply:
[1] [0] [2] [0] [253]
The validator should send the coins to path 3 by default.
5.47
REQUEST DEFAULT SORTER PATH [188]
This command is not available if the Validator is programmed in “L66 compatibility” mode.