Signal Source
1. AM signal generator (AM SG)
2. FM signal generator (FM SG)
3. Sweep generator (10.7 Mhz for FM)

Output Indicator
1. SSVM
2. Oscilloscope
3. Frequency Counter

General preparation

1. Check source voltage.
2. Set function switch to band being aligned
3. Turn volume control to minimum (unless noted otherwise)
4. Connect low side of signal and output indicator to chassis ground unless otherwise specified.
    Keep ground connection close to high side connection.
5. Keep signal inout as low as possible to avoid AGC and AFC action
    (set output indicator to high sensitivity.)
6. Standard modulation is 1000 Hz AT 30% amplitude for AM (1000 Hz at 22.5 kHz deviation for FM)

AM IF ALIGNMENT 

Step

Signal source (AM RF Gen) Connect 

to 

Set signal to

Aligment indicator connect to 

Oscilloscope or SSVM

Set radio  dial to 

Adjust

Adjust for 

Remarks

1

A standard radiation loop

455 KHz

TP3 Detector Output Terminal

Quiet point

T2

Maximum

Volume control min 

position

2

Repeat for maximum output

AM RF ALIGNMENT 

Signal source (AM Signal Gen.) 

connect to 

Set signal to 

Alignment indicator Connect to

Set radio dial to 

Adjust 

Adjust for

Remarks

1

515 KHz 

(modulated)

515 KHz 

(lowest end)

T1            (Osc, 

coil)

2

1745 KHz 

(modulated)

1745 KHz 

(Highest end)

C3           (Osc, 

trim)

3

600 KHz 

(modulated)

600 KHz

L4 (ant coil)

4

1440 KHz 

(modulated)

1400 KHz

C4 (ant trim)

5

Repeat Steps 3 and 4 as necessary to minimize tracking error. Also repeat steps 1 and 2 if necessary.

FM ALIGNMENT PROCEDURE

Step

Signal source (FM RF Gen.) 

Connect to

Set signal to

Alignment Indicator connect to 

Oscilloscope or SSVM

Set Radio dial 

to

Adjust

Adjust for

Remarks

1

T2

Maximum Symmetrical response

2

T4 (det. Coil)

Symmetrical response centered 

10.7Mhz

3

Repeat Step 1 and 2 as necessary to obtain S curve linearity , with maximum output

FM RF ALIGNMENT 

Step

Signal source (FM Signal Gen.) 

Connect to

Set signal to

Alignment indicator (oscilloscope , 

VTVM Connect to

Set radio dial to 

Adjust

Adjust for 

Remarks

1

87 MHz 

modulated

 *87MHz (lowest 

end)

L1 (Osc, coil)

2

109 MHz 

modulated

109MHz 

(Highest end)

C2           (Osc, 

trimmer)

3

90 MHz 

modulated

90MHz

L2 (RF coil) 

stretch or 

squeeze

4

106 MHz 

modulated

106MHz

C1 (RF trim)

5

repeat steps 3 and 4 as necessary to minimum tracking error. Also repeat steps 1 and 2 if necessary.

 * UK models must not be able to tune below 87.5 MHz.

BATTERY SENTINEL LEN ADJUSTMENT SETTING OF the 27 pin of IC2 (FOR SWITCH -ON POINT)

1. Plug unit into an AC outlet.

2. Set clock as described in owner's manual

3. Connect a DC power supply to the battery snap (inside battery compartment - no battery connected.)

    Connect to DC voltmeter across battery snap.

4. Set DC power suply to 8.2 volts. Adjust 27 pin of IC2 to the point where the Battery Sentinel just turns on. Disconnect DC power supply and voltmeter.

5. Connect to a new battery . (Battery Sentinel Indicator will automatically be reset.)

A standard radiation loop antenna

Across speaker voice coil

Maximum

Volume control max- 

position

Volume control min- 

position

TP 1, GND (Test point) through 

matching network if necessary

Across speaker voice coil

Maximum

Volume control Max- 

position

TP2 and GND

Sweep 

centered 10.7 

MHz

TP4 Detector Output Terminal

Quiet point