background image

Assembly Instruction

HADA 5100 SPTS

Summary of Contents for GSS HADA 5100 SPTS

Page 1: ...Assembly Instruction HADA 5100 SPTS ...

Page 2: ... 1 Menu items 10 4 2 Control panel 10 5 Programming 11 5 1 Programming procedure 11 5 2 Programming the cassette 13 Selecting the cassette 13 Ethernet parameters 14 Hardware IP address 14 Address range 15 Address of the gateway 15 UDP port 16 Input 16 Output IP addresse 17 Switching the IP address off or on 17 Transmission protocol 17 Port number 17 Quantity of data packets 18 Forward error correc...

Page 3: ...ts No liability is accepted for any damage caused by faulty connections or inappropriate handling Observe the relevant standards regulations and guidelines on the installa tion and operation of antenna systems The standards IEC EN DINEN50083 resp IEC EN DINEN60728 must be observed For further information please read the assembly instructions for the head end station used Test the software versions...

Page 4: ...014 35 EU The product fulfils the guidelines and standards for CE labelling page 23 Unless otherwise noted all values are specified as typical LAN interface Standard 10 BASE T IEEE 802 3i 100 BASE TX IEEE 802 3u 1000 BASE X IEEE 802 3z Data rate 180 MBit Protocols UDP User Data Protocol RTP Real Time Transport Protocol ASI interfaces Standard DIN EN 50083 9 Format MPEG ISO IEC 13818 1 User data ra...

Page 5: ...TS MPTS transport streams five output IP addresses For operating the cassette in a LAN network it can be assigned its own hardware IP address Two IP address ranges are used Hardware IP addresses menu ETHERNET which are used to connect the cassettes in the network e g 192 168 0 x IPTV IP addresses menu IP OUT which are used to send the IPTV channels multicast range e g 227 40 50 x Principle signal ...

Page 6: ...software BE Flash and the current assembly instructions on the website www mygss eu The cassette is intended for use in the STANDARD LINE head end stations Five LEDs 6 8 0 indicate by their colour whether an input signal is present LED colour Indication Green Signal present Red no Signal 1 2 3 9 0 7 8 5 6 4 2 5 Software query Control unit If necessary you can activate the indication of the softwar...

Page 7: ...ion that vibrates in a similar way Before installing or changing a cassette unplug the power cable from the mains power socket Remove the fastening screws 1 of an unoccupied slot from the bracket of the head end station Insert the cassette in this slot and push it into the housing Align the cassette and apply slight pressure to connect it to the connections of the board and the RF bus bar Fasten t...

Page 8: ... leading in and out for the 19 cabinet are made using cable terminals CLASS KLASSE The attenuation of shielding of the connection lines for ASI and antenna must meet the requirements for Class A Insert the required number of cable terminals in the openings provided in the head end station or in the 19 cabinet Tighten the nuts on the cable terminals until the teeth on the lock washer have penetrate...

Page 9: ...nput 3 0 Status LED ASI input 3 ASI input 2 Status LED ASI input 2 ASI input 1 Status LED ASI input 1 D SUB socket RS 232 Type label MAC address at the frame The operating software of the cassette can be updated via the 9 pin D SUB socket RS 232 using a PC or notebook and the software BE Flash You can find the current operating software on the web site www mygss eu 3 4 Connecting the cassette Conn...

Page 10: ... to be set are underlined Use the key to select the following main menu items Ethernet parameter Output parameter Datamode Displaying the data rate Factory reset 4 2 Control panel The key pad on the head end station is used to scroll through the menus scrolls forward through the menus select parameters in the menus set values initiate actions selects sub menus scrolls backward through the menus sa...

Page 11: ...TWIN SAT C07 Böx 4 C5 12 S3 24 TWIN SAT C07 Box 5 t 10 s Bx 4 stat ETHERNET Options stat DHCP A Bx 4 192 168 0 1 IP GATEWAY Bx 4 255 255 255 0 IP MASK Bx 4 192 168 0 128 IP ADDR Bx 4 60000 UDP PORT B 0 65535 Ein On 1 5 INFO OK ASI 1 227 40 50 1 IP OUT ASI 1 on UDP MODE PORT 1234 Bx 4 ASI 1 INPUT OK on off UDP RTP 0 65535 auto Page 12 ...

Page 12: ...ACTORY Bx 4 STORE FACTORY M 1 5 INFO OK ASI 1 227 40 50 1 IP OUT ASI 1 on UDP MODE PORT 1234 Bx 4 ASI 1 INPUT OK on off UDP RTP 0 65535 Bx 4 constant DATAMODE ASI 1 7 off PKTS FEC off 10 9 20 19 Annex A Annex B constant unmodified 1 7 copy copy auto Page 11 Page 11 ...

Page 13: ...on returns to the previous menus Switch on the head end station BE Remote please wait V 45 t 10 s Ein On The display shows the software version e g V 45 The processor reads the cassettes data approx 10 seconds Selecting the cassette Box 4 V 1 ASI2LAN 0 128 Box 1 Bx 1A C5 12 S3 24 TWIN SAT C07 Böx 4 C5 12 S3 24 TWIN SAT C07 Box 5 Select the cassette you want to program e g Box 4 by repeatedly press...

Page 14: ...anual setting stat or automatic setting DHCP of the Ethernet parameters Press the button to activate the setting options Options The Hardware IP address IP ADDR sub menu is activated Hardware IP address To operate the cassette in a network an IP address must be assigned to each IPTV cassette If a manually setting of the Ethernet parameters is se lected set the IP address of the cassette in this me...

Page 15: ... the buttons to place the cursor under the digit of the IP mask displayed to be set and use to set the IP mask wished Press the button The Address of the gateway IP GATEWAY sub menu is activated Address of the gateway The address of a gateway server router can be set in this menu If no gate way is used you can skip this setting Bx 4 192 168 0 1 IP GATEWAY Use the buttons to place the cursor under ...

Page 16: ... The INPUT main menu is activated Input In this menu you select the input for which you would like to set the output parameters in the submenus Bx 4 ASI 1 INPUT OK The indication OK serve for information OK input signal is present at input 1 Use the buttons to select the input 1 5 for which you would like to set the output parameters To skip the settings of the input parameters press the but ton T...

Page 17: ...he following outputs are allocated with IP ad dresses in ascending order starting from the IP address set The display shows auto for a short time Press the button The Switching the IP address off or on Transmission protocol Port number MODE PORT submenu is activated Switching the IP address off or on Transmission protocol Port number In this menu you can switch off the IP address displayed and def...

Page 18: ...the digit of the port number displayed to be set Using the buttons set the port number wished Copying the settings to all IP outputs Pressing the button the settings can be copied to the IP autputs following from the selected on The display shows copy for a short time Press the button The Quantity of data packets Forward error correction Transmis sion channel PKTS FEC menu is activated Quantity of...

Page 19: ...he buttons set the value of the FEC wished off 10 9 20 19 ASI 1 7 10 09 AnnexB PKTS FEC Setting the transmission channel Press the button to position the cursor under Annex Use the buttons to set the transmission channel wished AnnexA AnnexB Copying the settings to all IP outputs Pressing the button the settings Quantity of the data packets Forward error correction and Transmission channel can be ...

Page 20: ...d will be customized is necessary Bx 4 constant DATAMODE Using the buttons select the data mode whished Press the button The Displaying the output data rate DATARATE menu is activated Displaying the output data rate In this menu the current data rate is displayed Bx 4 DATARATE xxx MBits The maximum data rate depends on the used available output 1 GBit LAN 180 MBit 100 MBit LAN 80 MBit Press the bu...

Page 21: ...rned to the menu item Ethernet parameters ETHERNET without invoking the fac tory defaults page 14 Press the button The factory defaults are saved The display shows STORE Back to Selecting the cassette page 13 By pressing the button you will be returned to the menu item Ethernet parameters ETHERNET without invoking the fac tory defaults page 14 Saving settings Press the button Back to Selecting the...

Page 22: ... settes it is necessary to tighten all cable connections cable terminals and cover screws in order to maintain compliance with current EMC regulations securely Securely tighten the cable bolted connections using an appropriate open ended spanner Mount the front cover see assembly instructions of the head end station ...

Page 23: ...e 43 D 90471 Nuremberg CLASS CLASS KLASSE KLASSE Phone 49 0 911 703 8877 Fax 49 0 911 703 9210 www gss de en info gss de Service Phone 49 0 911 703 2221 Fax 49 0 911 703 2326 service gss de Alterations reserved Technical data E O E by GSS Grundig Systems GmbH V1 001 2017 ...

Reviews: