41
Steps:
1.
Set the static DPC as ON, and press OK to enter the static DPC edit
interface.
2.
Move the cursor to START, and press OK to start correcting the
defective pixels.
3.
Press
OK
when you see the message of
CLOSE THE IRIS THEN
PRESS ENTER KEY
showing up on the screen.
The level of the STATIC DPC ranges from 0 to 60.
Some of the defective pixels may appear undistinguished for the
system to detect. You can adjust the SENS-UP to X2, X4, X6, X8, X10,
X15, X20, X25 or X30 to brighten the defective pixel for the system to
find it. You can set the AGC level from 0 to 8.
RS485
You can set the parameters of RS485 in this menu, including camera
ID, ID display status and baud rate (2400/4800/9600/19200/38400).
RS485
1. CAM ID
-------- |255
2. ID DISPLAY ON
3. BAUDRATE
2400
4. RETURN RET
RS485