9.8. Application (Alarm Settings)
The IP Camera is equipped with one alarm input and one relay output for cooperation with the alarm system to
catch event images. Please refer to the alarm pin definition below to connect alarm devices to the IP Camera if
needed. The alarm configuration page is also shown below.
Alarm Pin Definition :
Please refer to the label on the alarm terminal block and connect the alarm wiring accordingly.
Alarm Switch :
The Administrator can enable or disable the alarm function.
Alarm Type :
Select an alarm type, “Normal close” or “Normal open”, that corresponds with the alarm application.
Alarm Output :
Define the alarm output signal as “high” or “low” for the normal alarm output status according to the current
alarm application.
Triggered Action (Multi-option) :
The Administrator can specify alarm actions that will take place when motion is detected. All options are listed as
follows:
- Enable Alarm Output:
Select this item to enable alarm relay output.
- IR Cut Filter:
If you select this item, the camera’s IR cut filter (ICR) will be removed (on) or blocked (off) when the alarm input is
triggered.
NOTE: The IR Function (Refer to IR Function) cannot be set to <Auto> mode when this trigger action is enabled.
- Send Alarm Message by FTP:
The Administrator can choose to send an alarm message by FTP when a motion is detected.