- Upload Image by E-Mail:
After selecting this item, the Administrator can assign an e-mail address and configure various parameters as
shown in the figure below. When the alarm is triggered, event images will be sent to the appointed e-mail
address.
The <Pre-trigger buffer> recording function allows users to check what happened to trigger the alarm. The pre-
trigger buffer time range is from 1 to 20 frames.
On the other hand, the <Post-trigger buffer> is for uploading a certain amount of images after the alarm input is
triggered. The post-trigger buffer time range is from 1 to 20 frames.
Check the box <Continue image upload> to upload the triggered images during a certain time or keep uploading
until the trigger is off.
- Select <Upload for __sec> and enter the duration in the blank. The images of the duration will be uploaded by
E-Mail when the alarm input is triggered. The setting range is from 1 to 9999 seconds.
- Select <Upload while trigger is active> to keep the images being uploaded via E-Mail while the trigger is active,
i.e. until the alarm is stopped.
Set the Image frequency as the upload frame rate. The setting range is from 1 frame to 15 frames.
NOTE: Make sure SMTP or FTP configuration has been completed. See section 9.5. Mail and 9.6. FTP for further
details.
39
English
Summary of Contents for GCI-G1536F
Page 2: ......
Page 13: ...11 English...