5. Assembly and installation
5.1 Selection of vacuum lines
The vacuum needed for the transport of chlorine gas is built up by
the injector, and maintained by the vacuum lines. Rigid PVC
pipes or flexible PE hoses are used as vacuum lines.
The following tables show the recommended diameter of vacuum
lines, depending on the line length and dosing quantity.
5.1.1 Vacuum lines between vacuum regulator and dosing regulator
* For the calculation, a pressure loss of p = 12.5 mbar in the vacuum line was assumed.
5.1.2 Vacuum lines between dosing regulator and injector
** For the calculation, a pressure loss of p = 50 mbar in the vacuum line was assumed.
Warning
Observe section
Max. length [m] of the vacuum lines between
vacuum regulator and dosing regulator*
Dosing quantity [g/h]
40
100
250
500
1000
2000
4000
0
DN 8
DN 8
DN 8
DN 8
DN 8
DN 8
DN 10
10
DN 8
DN 8
DN 8
DN 8
DN 8
DN 8
DN 10
20
DN 8
DN 8
DN 8
DN 8
DN 8
DN 10
DN 15
30
DN 8
DN 8
DN 8
DN 8
DN 8
DN 10
DN 15
40
DN 8
DN 8
DN 8
DN 8
DN 8
DN 15
DN 15
50
DN 8
DN 8
DN 8
DN 8
DN 10
DN 15
DN 15
75
DN 8
DN 8
DN 8
DN 8
DN 10
DN 15
DN 15
100
DN 8
DN 8
DN 8
DN 8
DN 10
DN 15
DN 20
Max. length [m] of the vacuum lines between
dosing regulator and injector**
Dosing quantity [g/h]
40
100
250
500
1000
2000
4000
0
DN 8
DN 8
DN 8
DN 8
DN 8
DN 8
DN 8
10
DN 8
DN 8
DN 8
DN 8
DN 8
DN 8
DN 8
20
DN 8
DN 8
DN 8
DN 8
DN 8
DN 8
DN 10
30
DN 8
DN 8
DN 8
DN 8
DN 8
DN 8
DN 10
40
DN 8
DN 8
DN 8
DN 8
DN 8
DN 8
DN 10
50
DN 8
DN 8
DN 8
DN 8
DN 8
DN 10
DN 15
75
DN 8
DN 8
DN 8
DN 8
DN 8
DN 10
DN 15
100
DN 8
DN 8
DN 8
DN 8
DN 8
DN 10
DN 15