Grundfos up15-10su7p Installation And Operating Instructions Manual Download Page 8

Ap

plication

s

UP Series

5

33

Comfort System

The Comfort System uses a patented Comfort Valve® 
and pump to provide instant availability of hot water at 
the point of use.

Operation

The Comfort Valve® is installed at the fixture furthest 
away from the hot-water tank. With a built-in timer, the 
pump allows hot water to circulate along the loop 
through the valve using the cold-water side as a return 
line. As the temperature rises to 100 °F (38 ° C), the 
valve closes directing hot water to the tap, thus 
resulting in a constant availability of hot water.

Savings

The Comfort System saves up to 16,000 gallons 
(60,566 liters) of water per year and per household 
(based on average modern household usage) and 
uses less energy than a 25 W light bulb.

Applications

• Domestic hot-water recirculation systems in single- 

and two-family houses.

Pumped liquids

• Domestic hot water

• Potable and non-potable water

Fig. 7 

Comfort System

Motor

• Insulation class: F.

• Power consumption: 25 W.

• Voltage: 115 V.

• Current 0.23 A.

• Phase: 1.

Grundfos Comfort Valve body materials

Ambient and liquid temperatures

Liquid temperature: 36 °F (2 °C) to 150 °F (66 °C).

It is recommended to keep the operating temperature 
as low as possible (e.g. 140 °F (60 °C)) to avoid 
calcium precipitation.

The ambient temperature should always be lower than 
the liquid temperature, as otherwise condensation may 
form in the stator housing.

Maximum system pressure

145 psi (10 bar).

Fig. 8 

Performance curve for the Comfort System

TM

03 91

26 340

7

Description
(UP open systems)

Material

Inlet cone, bearing plate, bearing 
retainers, rotor can, rotor 
cladding, shaft retainer

Stainless steel

Volute retainer (SU & SF models) 
and stator housing

Aluminium

Shaft, upper and lower radial 
bearings

Aluminium oxide ceramic

Thrust bearing

Carbon bearing and EPDM 
retainer

Pump housing (volute)

Silicon bronze C875 or stainless 
steel 300 series.

O-ring and gaskets

EPDM (ethylene propylene 
rubber)

Impeller

PES composite (30 % glass-filled)

Terminal box

Noryl® with EPDM gasket

Description

Trade name

Material

Springs, pins, screens 300 Series

Stainless steel

Valve body

Ryton

PPS

Thermal actuator 
body

300 Series

Stainless steel

Check valve O-ring

EPDM

Check valve body

Acetal

Check valves plunger

Thermoplastic

TM

0

3

 5

547

 3

806

0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

4.0

4.5

5.0

5.5

Q [US GPM]

0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

4.0

4.5

5.0

[ft]

H

0.0

0.2

0.4

0.6

0.8

1.0

1.2

Q [m³/h]

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

[m]

H

UP15-10SU7P/TLC

60 Hz

http://waterheatertimer.org/Water-heater-recirculation-system.html

Summary of Contents for up15-10su7p

Page 1: ...mfort System Hot Water Recirculation System ANSI NSF61 and IAPMO listed GRUNDFOS INSTRUCTIONS US Installation and operating instructions http waterheatertimer org Water heater recirculation system htm...

Page 2: ...t Inspection Examine the components carefully to make sure no damage has occurred to the pump during shipment Care should be taken to ensure the pump is NOT dropped or mishandled dropping will damage...

Page 3: ...using the 3 4 female fitting and gasket supplied on the pump ensuring that the pump shaft is horizontal The pump should be installed so that the pump is pumping away from the hot water heater towards...

Page 4: ...f your home has a branched hot water line more than one valve may be necessary Valve Installation Note Do not use teflon tape or pipe dope on the valve threads 1 Close both the hot and cold water angl...

Page 5: ...angle stop valves 10 Valve may be mounted to the wall with supplied mounting screws if desired Valve Operation If there is no hot water at the faucet or there appears to be too much hot water on the...

Page 6: ...used Electrical Connection Insert the 115V plug on the line cord from the pump into a properly grounded 115V outlet Timer Technical Data TIMER CONTROL Supply Voltage 115 120 VAC 60 hertz Contact Ratin...

Page 7: ...abs pushed away from the center indicate the circulator is switched ON while tabs pushed toward the center indicate the circulator is switched OFF 4 Set the manual switch to the TIMER position The cir...

Page 8: ...erating temperature as low as possible e g 140 F 60 C to avoid calcium precipitation The ambient temperature should always be lower than the liquid temperature as otherwise condensation may form in th...

Page 9: ...or repair or if the product was not installed in accordance with GRUNDFOS printed installation and operation instructions To obtain service under this warranty the defective product must be returned t...

Reviews: