Grundfos up15-10su7p Installation And Operating Instructions Manual Download Page 3

Pump Mounting: For Indoor Use

 
 

Note: Do not energize pump  

 

until properly installed

1.  Close  the supply water valve to the water 
heater located, in most cases, above the hot 
water heater on the cold water inlet to the 
hot water heater.

2.  Drain the water from the hot water pipe 
by opening a hot water faucet in the house.  
Let the water run until it stops flowing. 
Then drain remaining water from hot water 
heater spigot.  Leave the faucet open until 
pump installation is complete. If water does 
not stop flowing, check to make sure the 
water to the hot water heater has been 
completely shut off.

3.  Disconnect the hot water heater at the hot water discharge. (see Picture #1)

4.  Install pump onto the water heater discharge, using the 3/4” female fitting and 
gasket supplied on the pump ensuring that the pump shaft is horizontal. The pump 
should be installed so that the pump is pumping away from the hot water heater, 
towards the house. Confirm the direction of pumping by observing the flow arrow on 
the side of the pump housing. Be sure that the pump is not touching the exhaust vent 
piping (chimney) of a gas or oil fired hot water heater. (See Picture #2)

5.  Connect the hot water line to the 3/4” 
NPT discharge of the pump.  Use pipe 
dope or Teflon tape to seal threads when 
connecting to a 3/4 female NPT connection.  
If a gasketed flexible copper water heater 
connector is used pipe dope or Teflon tape is 
not required

6.  Reopen the supply valve to the hot water 
heater and allow the water to run until all 
the air has been purged from the piping.

7.  Close faucet inside the house.

page 2

Picture 2

Picture 1

Disconnect

Direction 

of 

water

Summary of Contents for up15-10su7p

Page 1: ...mfort System Hot Water Recirculation System ANSI NSF61 and IAPMO listed GRUNDFOS INSTRUCTIONS US Installation and operating instructions http waterheatertimer org Water heater recirculation system htm...

Page 2: ...t Inspection Examine the components carefully to make sure no damage has occurred to the pump during shipment Care should be taken to ensure the pump is NOT dropped or mishandled dropping will damage...

Page 3: ...using the 3 4 female fitting and gasket supplied on the pump ensuring that the pump shaft is horizontal The pump should be installed so that the pump is pumping away from the hot water heater towards...

Page 4: ...f your home has a branched hot water line more than one valve may be necessary Valve Installation Note Do not use teflon tape or pipe dope on the valve threads 1 Close both the hot and cold water angl...

Page 5: ...angle stop valves 10 Valve may be mounted to the wall with supplied mounting screws if desired Valve Operation If there is no hot water at the faucet or there appears to be too much hot water on the...

Page 6: ...used Electrical Connection Insert the 115V plug on the line cord from the pump into a properly grounded 115V outlet Timer Technical Data TIMER CONTROL Supply Voltage 115 120 VAC 60 hertz Contact Ratin...

Page 7: ...abs pushed away from the center indicate the circulator is switched ON while tabs pushed toward the center indicate the circulator is switched OFF 4 Set the manual switch to the TIMER position The cir...

Page 8: ...erating temperature as low as possible e g 140 F 60 C to avoid calcium precipitation The ambient temperature should always be lower than the liquid temperature as otherwise condensation may form in th...

Page 9: ...or repair or if the product was not installed in accordance with GRUNDFOS printed installation and operation instructions To obtain service under this warranty the defective product must be returned t...

Reviews: