2.5.2 Cable entry approval plate
IECEx BAS 17.0007U
Baseefa17ATEX0013U
BAS21UKEX0078U
Ex db IIB Gb
ID no.
DK-8850
Tamb= -5°C – +80°C
CE0344
II2G
UKCA1180
TM080590
Cable entry approval plate
The cable entry approval plate provides the following
details:
Pos.
Description
The equipment conforms to harmonised
European standard.
II
Equipment group (II = non-mining)
2
Equipment category (high protection)
G
Type of explosive atmosphere (gas)
CE
CE mark
UKCA
UKCA mark
0344
Number of quality assurance notified
body
1180
Number of quality assurance notified
body
Ex
Marking of explosion protection
db
Flameproof, Zone 1
IIB
Gas group (Ethylene)
T
amb
Ambient temperature
Gb
Equipment protection level, zone 1
ID no
Cable entry identification number (e.g.
36-1)
DK-8850
Country, postcode (Denmark, Bjerring-
bro)
2.6 Potentially explosive environments
In potentially explosive environments, use only Ex-
approved pumps. S pumps are available with the
following Ex approvals:
Range
Approval
ATEX/UKEX
IECEx
72
●
●
74-78
●
●
Ex pumps can be used in hazardous areas classified
as Zone 1 or Zone 2.
11
English (GB)
Summary of Contents for ST-55-520