background image

English (GB)

7

6. C-3, D-2

6.1 Removing the cover

1. Remove screw (pos. 400c).
2. Lift the cover free in one end and remove it.

6.2 Fitting the cover

1. Fit the cover. The locking pins must engage with tank top 

(pos. 402).

2. Fasten the cover.

6.3 Replacing the supply cable

1. Remove the cover. See section 

6.1 Removing the cover

.

2. Remove the cable clamp.
3. Separate the connector and push out the supply cable lead 

using a screwdriver with straight slot.

4. Separate the earth lead connector between the motor and 

supply cable.

5. Disconnect the neutral lead from pressure switch (pos. 482).
6. Fasten the new supply cable in the cable clamp.
7. Connect the earth lead, neutral lead and phase lead. 

See section 

9. Exploded views

.

8. Fit the connector on motor flange (pos. 156).
9. Fit the cover. See section 

6.2 Fitting the cover

.

6.4 Replacing the capacitor

1. Remove the cover. See section 

6.1 Removing the cover

.

2. Separate the connector and push out the two capacitor leads 

using a screwdriver with straight slot.

3. Remove the wire between the capacitor and pressure switch 

(pos. 482).

4. Carefully pull back the plastic lock and lift out the capacitor.
5. Fit the new capacitor.
6. Connect the two capacitor leads and the wire between the 

capacitor and pressure switch. See section 

8. Wiring 

diagrams

.

7. Fit the cover. See section 

6.2 Fitting the cover

.

6.5 Replacing the pressure switch

1. Remove the cover. See section 

6.1 Removing the cover

.

2. Disconnect the two pressure switch leads.
3. Turn the pressure switch 30 to 45 ° clockwise to loosen it from 

motor flange (pos. 156), and remove it.

4. Clean the sealing face of the motor flange.
5. Lubricate the O-ring on the pressure switch and the sealing 

face of the motor flange with Rocol Sapphire Aqua-Sil.

6. Fit the pressure switch in the motor flange and turn it 30 to 

45 ° counter-clockwise to lock it.

7. C-3: Set the start level by means of the selector switch. See 

fig. 

1

.

8. Connect the two leads to the pressure switch. See section 

9. Exploded views

.

9. Click the protective cover on the pressure switch.
10. Fit the cover. See section 

6.2 Fitting the cover

.

Fig. 1

Setting the start level

6.6 Replacing the motor

1. Remove the cover. See section 

6.1 Removing the cover

.

2. Separate the connector between the capacitor and motor.
3. Separate the earth lead connector between the motor and 

supply cable.

4. Remove motor flange (pos. 156) from tank top (pos. 402).
5. Remove screws (pos. 308b) of pump housing (pos. 2) and 

remove it from the motor flange.

6. Press the motor down and out of the motor flange.
7. Clean the inner recess of the motor flange using a soft cloth.
8. Lubricate the O-ring and the inner recess with Rocol Sapphire 

Aqua-Sil.

9. Fit the motor in the motor flange. The motor leads must point 

in the opposite direction as the cable clamp of the supply 
cable.

10. Fit the pump housing with the discharge pointing away from 

the pressure switch and tighten the screws.

11. Check that the grinder head does not touch the grinder ring.
12. Clean the sealing face of the tank top and the outer sealing 

face of the motor flange using a soft cloth.

13. Lubricate the O-ring on the motor flange and the sealing face 

of the tank top with Rocol Sapphire Aqua-Sil.

14. Fit the motor flange in the tank top and cross-tighten the 

screws.

15. Connect the earth lead to the connector. Fit the connector in 

the motor flange.

16. Fit the cover. See section 

6.2 Fitting the cover

.

Caution

Take care not to break the two locking pins.

Caution

Take care that the supply cable and other wires are 
not squeezed between the cover and tank top.

Position

Start level [mm]

LOW

65

HIGH

115

TM

06

71

57

 29

16

HIGH

LOW

Summary of Contents for Sololift2

Page 1: ...Sololift2 50 Hz 1 Service instructions GRUNDFOS INSTRUCTIONS...

Page 2: ...9 Replacing the grinder ring 6 5 10 DIP switch settings 6 6 C 3 D 2 7 6 1 Removing the cover 7 6 2 Fitting the cover 7 6 3 Replacing the supply cable 7 6 4 Replacing the capacitor 7 6 5 Replacing the...

Page 3: ...2 2 2 6 188 Screw M5 x 12 Stainless steel 3 0 4 0 301a O ring NBR Rocol Sapphire Aqua Sil 303a O ring NBR Rocol Sapphire Aqua Sil 306a O ring 95 x 2 5 NBR Rocol Sapphire Aqua Sil 308b Screw 4 7 x 65...

Page 4: ...the detergent work for approximately 5 minutes 4 Switch on the power supply and flush the toilet with clean water or turn on the water 5 Flush the toilet with clean water or turn on the water again u...

Page 5: ...ner pos 158 and pull the pressure switch vertically off motor flange pos 156 4 Clean the inner recess of the motor flange using a soft cloth 5 Lubricate pressure switch retainer pos 481 and the sealin...

Page 6: ...g away from the pressure switch and tighten the screws 14 Check that the grinder head does not touch the grinder ring 15 Clean the sealing face of the tank top and the outer sealing face of the motor...

Page 7: ...th Rocol Sapphire Aqua Sil 6 Fit the pressure switch in the motor flange and turn it 30 to 45 counter clockwise to lock it 7 C 3 Set the start level by means of the selector switch See fig 1 8 Connect...

Page 8: ...ricate the O ring and the inner recess with Rocol Sapphire Aqua Sil 8 Fit the motor in the motor flange The motor leads must point in the opposite direction as the cable clamp of the supply cable 9 Fi...

Page 9: ...e non return flap c Pressure switch defective Replace the pressure switch unit 4 Motor runs but does not evacuate water a Pump or tank blocked Remove blockage b Air lock in pump or vent hole in pump h...

Page 10: ...2 3 U4 V3 N2 L1 C 3 D 2 WC 1 WC 3 CWC 3 Capacitor Red Motor Capacitor Motor Blue Black Supply cable Blue Blue Supply cable Black Black Black Black Brown Blue Switch Black Brown Yellow and green Yello...

Page 11: ...English GB 11 9 Exploded views 9 1 WC 1 TM05 0003 0911...

Page 12: ...English GB 12 9 2 WC 3 TM05 0004 0911...

Page 13: ...English GB 13 9 3 CWC 3 TM05 0002 0911...

Page 14: ...English GB 14 9 4 C 3 TM05 0001 0911...

Page 15: ...English GB 15 9 5 D 2 TM05 0005 0911...

Page 16: ...16...

Page 17: ...nam ku 135 916 Seoul Korea Phone 82 2 5317 600 Telefax 82 2 5633 725 Latvia SIA GRUNDFOS Pumps Latvia Deglava biznesa centrs Augusta Deglava iel 60 LV 1035 R ga T lr 371 714 9640 7 149 641 Fakss 371 9...

Page 18: ...2693 The name Grundfos the Grundfos logo and be think innovate are registered trademarks owned by Grundfos Holding A S or Grundfos A S Denmark All rights reserved worldwide Copyright Grundfos Holding...

Reviews: