4. Pumped liquids

Grey wastewater up to 90 °C.
Ordinary liquids for cleaning of the appliances 
connected. pH value: 4-10.

5. Installation

6. Electrical connection

Make sure that the product is suitable for the supply 
voltage and frequency available at the installation 
site.
The electrical connection must be carried out in 
accordance with local regulations.

7. Service

For service kits, see www.grundfos.com > WebCAPS 
> Service.

7.1 Service documentation

Service documentation is available at 
www.grundfos.com > WebCAPS > Service.
If you have any questions, please contact the 
nearest Grundfos company or service workshop.

Caution

The product must not pump harsh 
chemicals or solvents. See the quick 
guide.

Caution

Do not pull or lift the product by the supply 
cable.

Note

We strongly recommend that you install an 
LC A2 alarm device (accessory) if a 
washing machine, dishwasher, bathtub 
and/or a shower are connected to the 
lifting station.
The LC A2 will emit an acoustic alarm and 
switch off the washing machine or 
dishwasher if the water level in the tank 
becomes too high.

Caution

We strongly recommend that you change 
the level switch for applications involving 
foaming wastewater. In this case please 
use the pressure switch with product 
number 98144467.

Note

The product must be accessible for 
maintenance and repair.
The product must be placed in a frost-free 
room to prevent the pumped liquid from 
freezing.
Make sure that all external pipework is 
adequately insulated.
The discharge pipe must be made of rigid 
material, such as copper, or of rigid PVC 
with solvent-welded joints.
To prevent the transmission of vibrations 
to buildings, make sure that the pipework 
is thoroughly fixed and that fittings cannot 
move and are not in contact with building 
parts.

Warning
The product must be earthed.
The installation must include an earth 
leakage circuit breaker for protection 
against earth fault currents. This will 
ensure protection when using a Schuko 
plug or another plug with earth pin.
The product must be connected to a mains 
switch with a minimum contact gap of 3 
mm in all poles.
In case of overtemperature, a thermal 
switch cuts out the motor and cuts it in 
automatically when it has cooled 
sufficiently.

Warning
The product must only be serviced by 
trained service personnel.
If the supply cable is damaged, it must 
replaced by the manufacturer, the 
manufacturer’s service partner or a 
similarly qualified person. 
To ensure safe and reliable operation, 
always use original spare parts from 
Grundfos.

Note

The product must be thoroughly cleaned 
before it is returned for service. Otherwise 
the warranty will be void.

Summary of Contents for Sololift2 C-3

Page 1: ...Sololift2 C 3 Installation and operating instructions 60 Hz GRUNDFOS INSTRUCTIONS ...

Page 2: ...ons Installation and operation must comply with local regulations EN 12056 4 and accepted codes of good practice Warning The use of this product requires experience with and knowledge of the product Persons with reduced physical sensory or mental capabilities must not use this product unless they are under supervision or have been instructed in the use of the product by a person responsible for th...

Page 3: ...e pressure switch with product number 98144467 Note The product must be accessible for maintenance and repair The product must be placed in a frost free room to prevent the pumped liquid from freezing Make sure that all external pipework is adequately insulated The discharge pipe must be made of rigid material such as copper or of rigid PVC with solvent welded joints To prevent the transmission of...

Page 4: ...otecting tube of the float switch and the tank Float switch pipe blocked If the water level in the tank is above the motor flange disconnect the power supply and drain the tank by means of the drain hose 1 Unscrew the cover Turn the bayonet coupling 10 clockwise Pull out the float switch unit Press in the two tabs on the protecting tube Pull down the protecting tube 2 Check and clean the float swi...

Page 5: ...system head 6 0 m Supply cable 1 5 m 0 75 mm2 H05VV F 3G Net weight 6 6 kg Start and stop levels Start level 1 65 mm above floor level Start level 2 115 mm above floor level Stop level 35 mm above floor level Liquid temperature 75 C continuously 90 C for 30 min Ambient temperature 5 C to 40 C Duty S3 50 1 min 30 sec on 30 sec off Marking Approvals Note The system pressure should not exceed 6 m hea...

Page 6: ...sly or at irregular intervals a Water leaking from inlet into tank Check for leaking appliances b Water leaking back into tank from discharge pipe Check the non return flap c Float switch defective or stuck Clean the float switch unit or replace it if necessary 4 Motor runs but does not evacuate water a Pump or tank blocked Remove blockage b Air lock in pump or vent hole in pump housing blocked Ch...

Page 7: ...rvice workshop Subject to alterations 8 Water from shower or another appliance connected to the lower inlets drains off slowly Backflow from the lifting station a Hydraulics blocked Check that the motor shaft can rotate freely Remove the motor flange to clean the impeller b The start level has changed Check and clean the float switch pipe c Inlet pipe diameter is too small Use a pipe with a larger...

Page 8: ...Appendix 8 Appendix 1 ...

Page 9: ...Appendix 9 ...

Page 10: ...Appendix 10 ...

Page 11: ...Consejo sobre la aproximación de las legislaciones de los Estados miembros de la UE Low Voltage Directive 2014 35 EU Standards used EN60335 1 2002 A1 2004 A11 2004 A12 2006 A2 2006 A13 2008 EN 60335 2 41 2003 A1 2004 A2 2010 EN 62233 2008 EMC Directive 2014 30 EU Standards used EN 61000 3 2 2006 A1 2009 A2 2009 EN 61000 3 3 2008 EN 55014 2 1997 A1 2001 A2 2008 EN 55014 1 2006 A1 2009 This EU decla...

Page 12: ... the performance requirements as described in the following Standard used EN 12050 2 2000 10 The performance of the product identified in points 1 and 2 is in conformity with the declared performance in point 9 AR رار إق EC ق للملح ا وفق ألداء ل ة األوروبي ة المجموع 3 ة لالئح EU اد االتح م رق ي األوروب 305 2011 ييد التش ات منتج ة الئح ج المنت وع لن د الفري ريف التع ز رم 1 EN 12050 2 ح يتي ر آخ ر ع...

Page 13: ...0 Las prestaciones del producto indicado en los puntos 1 y 2 cumplen lo declarado en el punto 9 PT Declaração de desempenho UE em conformidade com o Anexo III do Regulamento UE N º 305 2011 Regulamento de Produtos da Construção 1 Código de identificação exclusivo do tipo de produto EN 12050 2 2 Tipo lote ou número de série ou qualquer outro elemento que permita a identificação do produto de constr...

Page 14: ...OS Pumps Eesti OÜ Peterburi tee 92G 11415 Tallinn Tel 372 606 1690 Fax 372 606 1691 Finland OY GRUNDFOS Pumput AB Trukkikuja 1 FI 01360 Vantaa Phone 358 0 207 889 500 Telefax 358 0 207 889 550 France Pompes GRUNDFOS Distribution S A Parc d Activités de Chesnes 57 rue de Malacombe F 38290 St Quentin Fallavier Lyon Tél 33 4 74 82 15 15 Télécopie 33 4 74 94 10 51 Germany GRUNDFOS GMBH Schlüterstr 33 ...

Page 15: ...26 sk grundfos com Slovenia GRUNDFOS LJUBLJANA d o o Leskoškova 9e 1122 Ljubljana Phone 386 0 1 568 06 10 Telefax 386 0 1 568 06 19 E mail tehnika si grundfos com South Africa GRUNDFOS PTY LTD Corner Mountjoy and George Allen Roads Wilbart Ext 2 Bedfordview 2008 Phone 27 11 579 4800 Fax 27 11 455 6066 E mail lsmart grundfos com Spain Bombas GRUNDFOS España S A Camino de la Fuentecilla s n E 28110 ...

Page 16: ...61661 0516 ECM 1183978 The name Grundfos the Grundfos logo and be think innovate are registered trademarks owned by Grundfos Holding A S or Grundfos A S Denmark All rights reserved worldwide Copyright Grundfos Holding A S ...

Reviews: