Calibration process - example for DDC 6-10
1. Fill a measuring beaker with dosing medium.
Recommended filling volumes V
1
:
– DDC 6-10: 0.3 l
– DDC 9-7: 0.5 l
– DDC 15-4: 1.0 l
T
M
0
4
11
5
4
11
1
0
2. Read off and note down the fill volume V
1
(e.g. 300 ml).
3. Place the suction hose in the measuring beaker.
4. Start the calibration process in the "
Setup
>
Calibration
" menu.
5. The pump executes 200 dosing strokes and
displays the factory calibration value
(e.g. 125 ml).
6. Remove the suction hose from the measuring
beaker and check the remaining volume V
2
(e.g. 170 ml).
7. From V
1
and V
2
, calculate the actual dosed
volume V
d
= V
1
- V
2
(e.g. 300 ml - 170 ml = 130 ml).
8. Set and apply V
d
in the calibration menu.
• The pump is calibrated.
V
2
= 170 ml
V
d
= V
1
- V
2
= 130 ml
V
1
= 300 ml
Calibration
Calibration
Strokes:
Calibrat. volume:
200
STOP
START
0.0000 ml
Strokes:
Calibrat. volume:
0
125 ml
Calibration
Calibrat. volume:
STOP
START
ml
Strokes:
200
130
Actual dosed volume V
d
STOP
START