English (GB)
19
Fig. 8
Wiring diagram, 10-core cable, star-connected (Y)
Fig. 9
Wiring diagram, 10-core cable, delta-connected (D)
To find out whether the pump is fitted with a thermal switch or a
PTC thermistor, measure the motor winding resistance.
See table below.
TM
04 68
86 071
0
Yellow/green
Standard version
Thermal switches*
Sensor version
Thermal switch, Pt1000 resistor,
moisture switch and water-in-oil sensor
Sensor version
Thermal switch, PTC thermistor*,
moisture switch and water-in-oil sensor
* Pumps from 4 kW and up sold in Australia/New Zealand are fitted with a PTC thermistor.
TM
04
68
87
07
10
Yellow/green
Standard version
Thermal switches*
Sensor version
Thermal switch, Pt1000 resistor,
moisture switch and water-in-oil sensor
Sensor version
Thermal switch, PTC thermistor*,
moisture switch and water-in-oil sensor
* Pumps from 4 kW and up sold in Australia/New Zealand are fitted with a PTC thermistor.
Without cable
With 10 m
cable
With 15 m
cable
Thermal switch
< 50 m
Ω
< 320 m
Ω
< 390 m
Ω
PTC thermistor
> 100 m
Ω
> 370 m
Ω
> 440 m
Ω