10.4 Cleaning the level sensor
1. Push the ON-OFF-AUTO selector switch to position OFF ( ).
See section
2. Loosen the screw cap by turning it counterclockwise.
See fig.
.
3. Lift the pressure tube carefully out of the collecting tank.
Do not lift it by means of the hose.
4. Check for possible deposits on or in the pressure tube. See
section
5. Scrape off any deposits. If necessary, remove the hose from
the controller, and rinse the tube and hose with clean water at
low pressure. Make sure no water remains in the hose.
6. Refit the pressure tube by screwing the screw cap on to the
tank. Reconnect the hose to the controller.
7. Check the sensor by test running Multilift MD, MLD.
Fig. 35
Removing the level sensor
10.5 Contaminated lifting station or components
If Grundfos is requested to service the lifting station, Grundfos
must be contacted with details about the pumped liquid, etc. before
the lifting station is returned for service. Otherwise Grundfos can
refuse to accept the lifting station for service.
Lifting stations which have been in contact with the pumped liquid
must be thoroughly cleaned before they are returned to Grundfos.
Any costs of returning the lifting station are to be paid by the
customer.
However, any application for service (no matter to whom it may
be made) must include details about the pumped liquid if the
lifting station has been used for liquids which are injurious to
health or toxic.
TM
05
05
45
10
11
Warning
If a Multilift lifting station has been used for a liquid
which is injurious to health or toxic, it will be
classified as contaminated.
Summary of Contents for Multilift MD
Page 2: ...2...
Page 4: ...Table of contents 4 Multilift MD MLD UA 621 CN 647 JP 671 Appendix 699...
Page 36: ...BG 36 5 2 1 LC 221 Multilift MD22 MLD22 5 2 LC 221...
Page 39: ...BG 39 6 LC 221 6 1 LC 221 11 11 LC 221 TM05 1861 3811 1234 AUTO 6 3 6 2...
Page 40: ...BG 40 1 1 1 2 2 2 6 4...
Page 184: ...Espa ol ES 184...
Page 244: ...GR 244 6 LC 221 6 1 LC 221 11 11 LC 221 TM05 1861 3811 1234 AUTO 6 3 6 2 Alarm...
Page 245: ...GR 245 1 1 1 2 2 2 6 4...
Page 629: ...UA 629 6 LC 221 6 1 LC 221 11 11 LC 221 TM05 1861 3811 1234 AUTO 6 3 6 2 Setup...
Page 630: ...UA 630 1 1 1 2 2 2 6 4...
Page 655: ...CN 655 6 LC 221 6 1 LC 221 11 11 LC 221 TM05 1861 3811 1234 AUTO 6 3 6 2...
Page 656: ...CN 656 1 1 1 2 2 2 6 4...
Page 660: ...CN 660 Man Auto ON OFF AUTO OFF ON OFF AUTO OFF 30 14 TM05 3455 0616...
Page 680: ...JP 680 6 LC 221 6 1 LC 221 11 11 LC 221 TM05 1861 3811 1234 AUTO 6 3 6 2...
Page 681: ...JP 681 2 1 1 1 2 2 2 6 4...
Page 685: ...JP 685 LED Man Auto LED ON OFF AUTO OFF ON OFF AUTO OFF LED 30 14 TM05 3455 0412...
Page 698: ...JP 698 13 1 2...
Page 699: ...Appendix 699 Appendix 1 Fig A Dimensional sketches MD TM05 0441 1011...
Page 700: ...Appendix 700 Fig B Dimensional sketches MLD TM05 0442 1011...
Page 701: ...701...
Page 702: ...702...