English (GB) 

Installation and operating instructions

Original installation and operating instructions

These installation and operating instructions 
describe Grundfos JPC pumps.
Sections 1-3 give the information necessary to be 
able to unpack, install and start up the product in a 
safe way.
Sections 4-8 give important information about the 
product, as well as information on service, fault 
finding and disposal of the product.

CONTENTS

Page

1. General information

1.1 Symbols used in this document

2. Installing the product

2.1 Checking the product prior to 

installation

Before installing the pump, check that the rotating 
parts turn freely. Position numbers refer to fig. 

1

.

1. Remove the fan cover (pos. 13) from the motor.
2. Insert a screwdriver in the notch on the motor 

shaft from the ventilation side.

3. If there is a blockage, turn the screwdriver, 

tapping it gently with a hammer.

Fig. 1

Checking the rotating parts

1.

General information

4

1.1 Symbols used in this document

4

2.

Installing the product

4

2.1 Checking the product prior to installation

4

2.2 Location

5

2.3 Mechanical installation

5

2.4 Electrical connection

6

3.

Starting up the product

6

3.1 Priming the pump

6

3.2 Shaft seal run-in

6

4.

Servicing the product

7

4.1 Maintaining the product

7

4.2 Spare parts and kits

7

5.

Product introduction

7

5.1 Identification

7

6.

Fault finding

8

7.

Technical data

9

8.

Disposing of the product

9

Warning
Prior to installation, read this document 
and the quick guide. Installation and 
operation must comply with local 
regulations and accepted codes of good 
practice.

Warning
This appliance is not intended for use by 
persons (including children) with reduced 
physical, sensory or mental capabilities, or 
lack of experience and knowledge, unless 
they have been given supervision or 
instruction concerning use of the appliance 
by a person responsible for their safety.

Warning
Children should be supervised to ensure 
that they do not play with the appliance.

Warning
The maximum inlet pressure must not be 
exceeded.
JPC 3-42: 1.8 bar / 180 kPa.
JPC 4-47: 1.3 bar / 130 kPa.
JPC 4-54: 0.6 bar / 60 kPa.

Warning
If these safety instructions are not 
observed, it may result in personal injury.

Warning
If these instructions are not observed, it 
may lead to electric shock with consequent 
risk of serious personal injury or death.

Caution

If these safety instructions are not 
observed, it may result in malfunction or 
damage to the equipment.

Note

Notes or instructions that make the job 
easier and ensure safe operation.

Warning
The product must be installed and 
maintained by authorised staff.

TM

0

6

 4

529

 2

515

Summary of Contents for JPC 3-42

Page 1: ...JPC Installation and operating instructions GRUNDFOS INSTRUCTIONS...

Page 2: ...2...

Page 3: ...3 Table of contents JPC English GB Installation and operating instructions 4 AR 15 Declaration of conformity 16...

Page 4: ...eal run in 6 4 Servicing the product 7 4 1 Maintaining the product 7 4 2 Spare parts and kits 7 5 Product introduction 7 5 1 Identification 7 6 Fault finding 8 7 Technical data 9 8 Disposing of the pr...

Page 5: ...e inlet pipe is longer than 10 metres or the suction lift is greater than 4 metres the diameter of the pipe must be larger than 1 If a hose is used as inlet pipe it must be non collapsible To prevent...

Page 6: ...red before the leakage is reduced to an acceptable level The time required for this depends on the operating conditions i e every time the operating conditions change a new run in period will be start...

Page 7: ...1 Identification Fig 7 Nameplate Warning If the power supply cable is damaged it must be replaced by the manufacturer the manufacturer s service partner or a similarly qualified person Warning Service...

Page 8: ...e the strainer in the inlet pipe d The suction lift is too high over 7 metres Change the position of the pump e The inlet pipe is too long Change the position of the pump f Diameter of inlet pipe is t...

Page 9: ...ing a pressure loss at a liquid temperature of 20 C Supply voltage 1 x 115 V 60 Hz 1 x 230 V 50 Hz 1 x 230 V 60 Hz Insulation class F Enclosure class IP44 Relative air humidity Maximum 95 Maximum soun...

Page 10: ...C 55 40 C 60 0 35 0 C 40 0 6 600 JPC 3 42 42 JPC 4 47 47 JPC 4 54 54 JPC 3 42 1 8 180 JPC 4 47 1 3 130 JPC 4 54 0 6 60 8 20 115 1 60 230 1 50 230 1 60 F IP44 95 JPC 3 42 82 9 JPC 4 47 84 8 JPC 4 54 88...

Page 11: ...Arabic AR 11 6 6 a 1 b c 3 a 2 b c d 7 e f g h a 3 a 4...

Page 12: ...5 6 7 8 9 10 11 12 13 14 15 16 17 DK 8850 Bjerringbro Denmark Type JPC 4 47 No 99074057 P4 1 1628 U 1x220 240 V I1 1 3 8A 50Hz P1 0 85 12 5 F 450 V Class F IP 44 P2 0 8HP Q 0 4 3 6 m h H 41 20 m Tmax...

Page 13: ...Arabic AR 13 2 4 2 4 3 ELCB 30 5 3 3 20 5 3 1 3 1 6 1 1 2 2 3 3 TM06 4534 2515 6 6 3 2 3 2...

Page 14: ...Arabic AR 14 55 40 2 3 4 2 2 2 2 TM06 4530 2515 2 2 2 2 1 2 2 1 TM06 4536 2515 3 3 2 3 2 3 2 3 1 2 3 1 10 4 1 4 TM06 4531 2515 4 4 2 3 2 2 3 2 5 TM06 4532 2515 5 5...

Page 15: ...8 4 15 1 15 1 1 15 2 15 2 1 14 2 2 14 2 3 13 2 4 13 3 13 3 1 13 3 2 12 4 12 4 1 12 4 2 12 5 12 5 1 11 6 10 7 10 8 1 JPC 3 42 1 8 180 JPC 4 47 1 3 130 JPC 4 54 0 6 60 1 1 1 1 1 1 2 2 2 1 2 1 13 1 1 2 2...

Page 16: ...ation of the laws of the EU member states AR EU JPC EU Low Voltage Directive 2014 35 EU Standards used EN60335 1 2002 A1 2004 A11 2004 A2 2006 A12 2006 A13 2008 A14 2010 A15 2011 EN60335 2 41 2003 A1...

Page 17: ...17...

Page 18: ...i tee 92G 11415 Tallinn Tel 372 606 1690 Fax 372 606 1691 Finland OY GRUNDFOS Pumput AB Trukkikuja 1 FI 01360 Vantaa Phone 358 0 207 889 500 Telefax 358 0 207 889 550 France Pompes GRUNDFOS Distributi...

Page 19: ...5020 1426 sk grundfos com Slovenia GRUNDFOS LJUBLJANA d o o Lesko kova 9e 1122 Ljubljana Phone 386 0 1 568 06 10 Telefax 386 0 1 568 06 19 E mail tehnika si grundfos com South Africa GRUNDFOS PTY LTD...

Page 20: ...6663 0816 ECM 1189208 The name Grundfos the Grundfos logo and be think innovate are registered trademarks owned by Grundfos Holding A S or Grundfos A S Denmark All rights reserved worldwide Copyright...

Reviews: