4.3 Using the product

View the logged data on the following website:

http://igrid.grundfos.com.

Logging into the website requires a user name and 
password supplied separately by Grundfos.
Once you are logged in, data from the data logging 
devices become available by clicking on "My 
devices" at the top of the webpage.
You can now click on the following options next to a 
device:

"Graphics"

"Data"

"Settings".

The "Graphics" tab is displayed by default.

Graphics

The graphs are designed with the pressure and 
temperature curves in separate coordinate systems. 
A minimised version of the curves is displayed under 
each coordinate system. The required period that the 
curves have to span can be set.
Use the slider on the right and left side of the time 
interval to narrow or extend the displayed time 
period. Alternatively, you can select different zoom 
ranges directly from the dropdown menu.

Data

Click "Data" to display the logged data. Data in the 
columns are displayed with type designation 
depending on the type of unit (for example pit 
measure point or bypass cabinet) chosen, for 
example T-flow or T-return.
The column with the U-CAP designation indicates 
the charged voltage level of the capacitors that act 
as an energy storage in TEG-based products. Data 
transmission starts at approximately 4 volt.

4.4 Identification

4.4.1 Nameplate

The information on the nameplate of the product is 
described below.

Fig. 5

Nameplate

TM

07

 4

11

0 1

5

1

9

Pos.

Description

1

Product name

2

Supply voltage

3

Maximum current

4

Ambient temperature [°C]

5

Markings and approvals

6

Country of production

7

Version number and material number

8

Production code, year and week

9

Serial number

10

Factory code

11

Enclosure class according to IEC

Type

P. N.

Made in Denmark

U

N

P.C.

S.N.

P1

DK - 8850 Bjerringbro Denmark

I Max

IP

T

amb

xxxxxxxx

°C

1
2
3
4

5
6

7
8
9
10
11

Summary of Contents for iGRID Pit measure point

Page 1: ...iGRID Pit measure point Installation and operating instructions GRUNDFOS INSTRUCTIONS...

Page 2: ...7 7 Fault finding the product 8 8 Technical data 9 8 1 Temperature 9 8 2 Enclosure class 9 8 3 Operating pressure test pressure 9 8 4 Minimum differential pressure 9 8 5 Minimum differential temperatu...

Page 3: ...Crushing of limbs Minor or moderate personal injury Lift the product using the handle The product can be placed on all sides except on the front We recommend placing it on the bottom side WARNING Hot...

Page 4: ...at there is sufficient air around the receiving part of the antenna and we therefore recommend placing the antenna in a conduit Refill the hole in the road afterwards See fig 2 Fig 2 Positioning the a...

Page 5: ...hambers District heating network without access to supply voltage 4 2 Intended use The product is powered by transforming heat to electricity via a thermoelectric generator that relies on the temperat...

Page 6: ...vely you can select different zoom ranges directly from the dropdown menu Data Click Data to display the logged data Data in the columns are displayed with type designation depending on the type of un...

Page 7: ...e taken out of the valve chamber We recommend that external Y strainers are cleaned as required WARNING Falling hazard Death or serious personal injury Carry out work in the valve chamber according to...

Page 8: ...the handle WARNING Falling hazard Death or serious personal injury Conclude work in the valve chamber according to local regulations Fault Cause Remedy 1 The product is not present in the device overv...

Page 9: ...opper electrogalvanised plated brass and stainless steel 9 Disposal This product or parts of it must be disposed of in an environmentally sound way 1 Use the public or private waste collection service...

Page 10: ...e seule responsabilit que le produit point de mesure fosse iGRID auquel se r f re cette d claration est conforme aux Directives du Conseil concernant le rapprochement des l gislations des tats membres...

Page 11: ...11...

Page 12: ...50 51 51 E mail info_GDK grundfos com www grundfos com DK Estonia GRUNDFOS Pumps Eesti O Peterburi tee 92G 11415 Tallinn Tel 372 606 1690 Fax 372 606 1691 Finland OY GRUNDFOS Pumput AB Trukkikuja 1 F...

Page 13: ...ozsk 4D 821 09 BRATISLAVA Phona 421 2 5020 1426 sk grundfos com Slovenia GRUNDFOS LJUBLJANA d o o Lesko kova 9e 1122 Ljubljana Phone 386 0 1 568 06 10 Telefax 386 0 1 568 06 19 E mail tehnika si grund...

Page 14: ...9518 Trademarks displayed in this material including but not limited to Grundfos the Grundfos logo and be think innovate are registered trademarks owned by The Grundfos Group All rights reserved 2020...

Reviews: