background image

En
gl

is

h (
G

B)

2

English (GB) 

Installation and operating instructions

Original installation and operating instructions.

CONTENTS

Page

1. Symbols used in this document

2. General description 

To ensure reliable and optimum operation, Grundfos 
drainage pumps, type DPK, are designed with two 
types of impeller:

0.75 - 15 kW models have semi-open impeller 

19 and 22 kW models have closed impeller.

DPK pumps are used for removal of surface and 
underground water in small and medium systems.
DPK pumps can be controlled via the pump 
controllers GU01 and GU02. For further information, 
see data sheet for GU01 / GU02 module at 
www.grundfos.com.

1.

Symbols used in this document

2

2.

General description

2

3.

Operating conditions

3

4.

Applications

4

5.

Safety

4

6.

Transportation and storage

4

6.1

Transportation

4

6.2

Storage

4

6.2.1

Warehouse storage

4

6.2.2

Storage in the tank

4

7.

Nameplate

5

8.

Approvals

6

9.

Type key

6

10.

Installation

7

10.1

Installation types

7

10.2

Submerged installation on auto coupling

7

10.3

Free-standing submerged installation

8

11.

Electrical connection

9

11.1

Pump controllers

10

11.2

GU01 and GU02

10

11.3

Frequency converter operation

10

11.3.1 Recommendations

10

11.3.2 Possible consequences

10

12.

Startup

11

12.1

Direction of rotation

11

13.

Operation

12

14.

Maintenance, inspection and overhaul 12

14.1

Maintenance

12

14.1.1 Current and voltage

12

14.1.2 Vibration

12

14.1.3 Discharge pressure and flow rate

12

14.1.4 Insulation resistance

12

14.2

Inspection

13

14.2.1 How to remove the pump

13

14.2.2 Inspection of seal sensor

13

14.2.3 Inspection of impeller and wear plate

13

14.3

Overhaul

13

15.

Fault correction

14

16.

Service

15

16.1

Service documentation

15

16.2

Contaminated pumps

15

17.

Disposal

15

Warning

Prior to installation, read these 
installation and operating instructions. 
Installation and operation must comply 
with local regulations and accepted 
codes of good practice.

Warning

If these safety instructions are not 
observed, it may result in personal 
injury.

Caution

If these safety instructions are not 
observed, it may result in malfunction 
or damage to the equipment.

Note

Notes or instructions that make the job 
easier and ensure safe operation.

Summary of Contents for DPK.10.50.075

Page 1: ...DPK Installation and operating instructions GRUNDFOS INSTRUCTIONS...

Page 2: ...7 10 3 Free standing submerged installation 8 11 Electrical connection 9 11 1 Pump controllers 10 11 2 GU01 and GU02 10 11 3 Frequency converter operation 10 11 3 1 Recommendations 10 11 3 2 Possible...

Page 3: ...can cope with pH values ranging from 4 to 10 Liquid temperature 0 C to 40 C Density of pumped liquid Maximum 1 000 kg m3 In the case of higher densities contact Grundfos Installation depth Maximum 25...

Page 4: ...Do this to prevent moisture from penetrating into the motor which will cause severe damage to the windings Give all unpainted surfaces a light coat of oil or grease to prevent corrosion If new pumps...

Page 5: ...uct number and serial number 4 Maximum head m 5 Enclosure class 6 Maximum installation depth m 7 Number of phases 8 Frequency Hz 9 Speed min 1 10 Weight 11 Rated voltage V Star 12 Rated voltage V Delt...

Page 6: ...stated on the pump nameplate See section 7 Nameplate Exception Code 075 0 75 kW Code Example DPK 10 80 22 S 5 0D DPK Drainage pump 10 Free passage Maximum solids size mm 80 Pump discharge Nominal dia...

Page 7: ...ounted on a stationary auto coupling guide rail system The auto coupling system facilitates maintenance and service as the pump can easily be lifted out of the tank See fig 4 Fig 4 Submerged pump on a...

Page 8: ...itate service on the pump and easy separation of pump and discharge line If a hose is used make sure that the hose does not buckle and that the inside diameter of the hose matches that of the pump dis...

Page 9: ...nnected pumps or fig 7 for star delta connected pumps For further information see the installation and operating instructions for the selected control box or pump controller at www grundfos com Fig 6...

Page 10: ...a relay GU01 and GU02 are manufactured for Grundfos For further information please contact your local Grundfos company 11 3 Frequency converter operation 11 3 1 Recommendations Before installing a fre...

Page 11: ...on in the following way every time the pump is connected to a new installation Procedure 1 Let the pump hang from a lifting device e g the hoist used for lowering the pump into the tank 2 Start and st...

Page 12: ...oltage Check the pump current and voltage If the ammeter reading exceeds the rated value or is far lower than the rated value there is a problem The voltage should be stable within 5 of the rated valu...

Page 13: ...screw 2 Tilt the pump with the oil filling hole pointing downwards in order to drain the pump of oil If the drained oil is contaminated or opaque this is an indication of an impending mechanical shaf...

Page 14: ...ns on the pump nameplate 2 Increased current consumption due to large voltage drop Measure the voltage between two motor phases Tolerance 5 5 3 Impeller blocked by impurities Clean the impeller 4 Wron...

Page 15: ...clude details about the pumped liquid if the pump has been used for liquids which are injurious to health or toxic Before a pump is returned it must be cleaned in the best possible way 17 Disposal Thi...

Page 16: ...0 80 22 50 Hz 486 244 88 145 213 47 48 80 DPK 10 80 22 60 Hz 491 247 103 145 230 53 48 80 DPK 15 80 37 629 279 119 160 260 49 75 80 DPK 15 80 55 802 279 119 160 260 49 75 80 DPK 15 80 75 802 378 141 2...

Page 17: ...259 70 223 408 466 80 80 238 DPK 10 80 22 60Hz 506 306 266 70 224 409 467 80 80 240 DPK 15 80 37 616 311 235 80 280 452 510 80 80 281 DPK 15 80 55 729 311 235 80 280 452 510 80 80 281 DPK 15 80 75 749...

Page 18: ...150 90 200 868 588 430 75 DPK 20 150 190 483 416 1026 226 150 300 1083 743 540 90 DPK 20 150 220 483 416 1026 226 150 300 1083 743 540 90 Z10 Z11 Z12 Z13 Z14 Z15 Z16 ZKN ZM DPK 10 50 075 25A 597 161 5...

Page 19: ...t dengan pernyataan ini sesuai dengan peraturan perundang undangan dan ketentuan hukum negara negara anggota Komunitas Eropa PL Deklaracja zgodno ci WE My Grundfos o wiadczamy z pe n odpowiedzialno ci...

Page 20: ...Declaration of conformity RU 20 Declaration of conformity RU DPK 15 09 2009 753 C DK 30 B 02496 22 12 2016 1 2013 143581 188...

Page 21: ...21...

Page 22: ...OY GRUNDFOS Pumput AB Mestarintie 11 FIN 01730 Vantaa Phone 358 0 207 889 900 Telefax 358 0 207 889 550 France Pompes GRUNDFOS Distribution S A Parc d Activit s de Chesnes 57 rue de Malacombe F 38290...

Page 23: ...421 2 5020 1426 sk grundfos com Slovenia GRUNDFOS d o o landrova 8b SI 1231 Ljubljana rnu e Phone 386 31 718 808 Telefax 386 0 1 5680 619 E mail slovenia grundfos si South Africa GRUNDFOS PTY LTD Cor...

Page 24: ...5234 0514 ECM 1134923 The name Grundfos the Grundfos logo and be think innovate are registered trademarks owned by Grundfos Holding A S or Grundfos A S Denmark All rights reserved worldwide Copyright...

Reviews: