English (GB)

11

12. Startup

Procedure

1. Remove the pump from the system.
2. Check that the impeller can rotate freely. Turn the 

impeller by hand.

3. Check the condition of the oil in the oil chamber. 

See section 

14.2.2 Inspection of seal sensor

.

4. Check whether the monitoring units, if used, are 

operating satisfactorily.

5. Check the setting of the level pickups, float 

switches or electrodes.

6. Check the direction of rotation, see section 

12.1 Direction of rotation

.

7. Reinstall

 

the pump in the system.

8. Switch on the electricity supply.
9. Open the isolating valves, if fitted.
10. Check that the motor is 2/3 covered with liquid. 

If the liquid level is below that, add liquid to the 
tank until the minimum level is reached.

11. Vent the pump by tilting it by means of the lifting 

chain and let trapped air escape.

12. Let the pump run briefly, and check if the liquid 

level is falling. A correctly vented pump will 
quickly lower the liquid level.

13. Start the pump.

12.1 Direction of rotation

Check the direction of rotation in the following way 
every time the pump is connected to a new 
installation.

Procedure:

1. Let the pump hang from a lifting device, e.g. the 

hoist used for lowering the pump into the tank.

2. Start and stop the pump while observing the 

movement (jerk) of the pump. If connected 
correctly, the impeller will rotate clockwise when 
viewed from above. Consequently, when started, 
the pump will jerk counter-clockwise. See fig. 9. 
If the direction of rotation is wrong, interchange 
any two phases in the power supply. 

Fig. 9

Checking the direction of rotation

Warning

Before starting work on the pump, 
make sure that the fuses have been 
removed or the mains switch has been 
switched to off. It must be ensured that 
the power supply cannot be 
accidentally switched on.

Make sure that all protective equipment 
has been connected correctly.

The pump must not run dry.

Caution

In case of abnormal noise or vibrations 
from the pump or power/water supply 
failure, stop the pump immediately. 
Do not attempt to restart the pump until 
the cause of the fault has been found 
and the fault corrected.

Note

The pump may be started for a very 
short period without being submerged 
in order to check the direction of 
rotation.

TM

04 41

18

 08

09

Summary of Contents for DPK.10.50.075

Page 1: ...DPK Installation and operating instructions GRUNDFOS INSTRUCTIONS...

Page 2: ...7 10 3 Free standing submerged installation 8 11 Electrical connection 9 11 1 Pump controllers 10 11 2 GU01 and GU02 10 11 3 Frequency converter operation 10 11 3 1 Recommendations 10 11 3 2 Possible...

Page 3: ...can cope with pH values ranging from 4 to 10 Liquid temperature 0 C to 40 C Density of pumped liquid Maximum 1 000 kg m3 In the case of higher densities contact Grundfos Installation depth Maximum 25...

Page 4: ...Do this to prevent moisture from penetrating into the motor which will cause severe damage to the windings Give all unpainted surfaces a light coat of oil or grease to prevent corrosion If new pumps...

Page 5: ...uct number and serial number 4 Maximum head m 5 Enclosure class 6 Maximum installation depth m 7 Number of phases 8 Frequency Hz 9 Speed min 1 10 Weight 11 Rated voltage V Star 12 Rated voltage V Delt...

Page 6: ...stated on the pump nameplate See section 7 Nameplate Exception Code 075 0 75 kW Code Example DPK 10 80 22 S 5 0D DPK Drainage pump 10 Free passage Maximum solids size mm 80 Pump discharge Nominal dia...

Page 7: ...ounted on a stationary auto coupling guide rail system The auto coupling system facilitates maintenance and service as the pump can easily be lifted out of the tank See fig 4 Fig 4 Submerged pump on a...

Page 8: ...itate service on the pump and easy separation of pump and discharge line If a hose is used make sure that the hose does not buckle and that the inside diameter of the hose matches that of the pump dis...

Page 9: ...nnected pumps or fig 7 for star delta connected pumps For further information see the installation and operating instructions for the selected control box or pump controller at www grundfos com Fig 6...

Page 10: ...a relay GU01 and GU02 are manufactured for Grundfos For further information please contact your local Grundfos company 11 3 Frequency converter operation 11 3 1 Recommendations Before installing a fre...

Page 11: ...on in the following way every time the pump is connected to a new installation Procedure 1 Let the pump hang from a lifting device e g the hoist used for lowering the pump into the tank 2 Start and st...

Page 12: ...oltage Check the pump current and voltage If the ammeter reading exceeds the rated value or is far lower than the rated value there is a problem The voltage should be stable within 5 of the rated valu...

Page 13: ...screw 2 Tilt the pump with the oil filling hole pointing downwards in order to drain the pump of oil If the drained oil is contaminated or opaque this is an indication of an impending mechanical shaf...

Page 14: ...ns on the pump nameplate 2 Increased current consumption due to large voltage drop Measure the voltage between two motor phases Tolerance 5 5 3 Impeller blocked by impurities Clean the impeller 4 Wron...

Page 15: ...clude details about the pumped liquid if the pump has been used for liquids which are injurious to health or toxic Before a pump is returned it must be cleaned in the best possible way 17 Disposal Thi...

Page 16: ...0 80 22 50 Hz 486 244 88 145 213 47 48 80 DPK 10 80 22 60 Hz 491 247 103 145 230 53 48 80 DPK 15 80 37 629 279 119 160 260 49 75 80 DPK 15 80 55 802 279 119 160 260 49 75 80 DPK 15 80 75 802 378 141 2...

Page 17: ...259 70 223 408 466 80 80 238 DPK 10 80 22 60Hz 506 306 266 70 224 409 467 80 80 240 DPK 15 80 37 616 311 235 80 280 452 510 80 80 281 DPK 15 80 55 729 311 235 80 280 452 510 80 80 281 DPK 15 80 75 749...

Page 18: ...150 90 200 868 588 430 75 DPK 20 150 190 483 416 1026 226 150 300 1083 743 540 90 DPK 20 150 220 483 416 1026 226 150 300 1083 743 540 90 Z10 Z11 Z12 Z13 Z14 Z15 Z16 ZKN ZM DPK 10 50 075 25A 597 161 5...

Page 19: ...t dengan pernyataan ini sesuai dengan peraturan perundang undangan dan ketentuan hukum negara negara anggota Komunitas Eropa PL Deklaracja zgodno ci WE My Grundfos o wiadczamy z pe n odpowiedzialno ci...

Page 20: ...Declaration of conformity RU 20 Declaration of conformity RU DPK 15 09 2009 753 C DK 30 B 02496 22 12 2016 1 2013 143581 188...

Page 21: ...21...

Page 22: ...OY GRUNDFOS Pumput AB Mestarintie 11 FIN 01730 Vantaa Phone 358 0 207 889 900 Telefax 358 0 207 889 550 France Pompes GRUNDFOS Distribution S A Parc d Activit s de Chesnes 57 rue de Malacombe F 38290...

Page 23: ...421 2 5020 1426 sk grundfos com Slovenia GRUNDFOS d o o landrova 8b SI 1231 Ljubljana rnu e Phone 386 31 718 808 Telefax 386 0 1 5680 619 E mail slovenia grundfos si South Africa GRUNDFOS PTY LTD Cor...

Page 24: ...5234 0514 ECM 1134923 The name Grundfos the Grundfos logo and be think innovate are registered trademarks owned by Grundfos Holding A S or Grundfos A S Denmark All rights reserved worldwide Copyright...

Reviews: