WARNING

 

If these safety instructions are not observed, it may result in personal injury.

 

Before carrying out any installation or maintenance operation, controller must be 

disconnected from the power supply.

 

Don’t open the cover while the pump is running.

 

Don’t put wire, metal bar  lament etc. into the controller.

 

NOTE

 

IMPORTANT

 

The manufacturer is not liable for malfunctioning if the product is not correctly 

installed or damaged, modified and/or put to run beyond the working range as given 

in this manual.

 

The manufacturer reserves the right to make any modifications to this product from 

time to time.

 

 
 

 

 

 

INTRODUCTION 

 

4

 

Applications  

 

4

 

Features ------------------------------------------------------------------------------------------- 

4

 

Parameter & specifications ----------------------------------------------------------------- 

5

 

INSTALLATION 

 

6

 

Following are the safety instructions which must be followed by the service 

partners or user while installing and operating. If ignored, physical injury or 

even death may happen. Read the safety instructions before handling the 

system.

 

Tools used in controller Installation 

 

6

 

Controller components 

 

LCD screen  

  

Terminals 

  

8

 

DIP switch settings ----------------------------------------------------------------------------- 

9

 

PARAMETER – CALIBRATION AND ERASING

 

---------------------------------------------------------- 

9

 

Calibration --------------------------------------------------------------------------------------- 

9

 

Erasing-------------------------------------------------------------------------------------------- 

10

 

CONNECTIONS – CONTROLS DEVICES AND APPLICATIONS -------- 

11

 

Installing liquid level probes switch ------------------------------------------------------- 

11

 

Power Connections 

 

12

 

Control PCB Connections-Water Supply -------------------------------------------------- 

12

 

Drainage / De-watering ---------------------------------------------------------------------- 

14

 

Pressure Boosting ------------------------------------------------------------------------------ 

16

 

BASIC OPERATION ----------------------------------------------------------- 

18

 

Manual mode                                   

18  

Auto mode                                  

18  

Displaying Run Hours of the pump -------------------------------------------------------- 

18

 

Displaying last  f i ve fault records 

 

19

 

Communication link -------------------------------------------------------------------------- 

20

 

Faults & protection ---------------------------------------------------------------------------- 

22

 

 

 

 

 

 

 

 

 

 

(Notes or attention to ensure safe operation)

 

Meaning of the messages and graphic shown on the LCD screen                                               23

 

Application  : Water supply/transfer (using probes or floats) ----------------------- 

23

 

Application : Sewage/drainage (using floats) ------------------------------------------ 

23

 

Application  : Pressure boosting (using pressure switch) -----------------------------

24

 

TROUBLE SHOOTING 

 

25

 

CAUTION

 

If these safety instructions are not observed, it may result in malfunction or damage 

of the equipment.

 

All electrical connections must be carried out by a skilled and qualified personnel. 

Never connect AC power to output L1,C,N terminals.

 

Ensure the motor, controller, capacitor ratings match the output power.

 

SAFETY

 

Summary of Contents for DPC 1-1 CSCR

Page 1: ...CR For Single Phase Pumps 0 37 2 2 kW For more information contact us The name Grundfos the Grundfos logo and we think innovate are registered trademarks owned by Grundfos Holding A S or Grundfos A S...

Page 2: ...controller Installation 6 Controller components 6 LCD screen 6 Terminals 8 DIP switch settings 9 PARAMETER CALIBRATION AND ERASING 9 Calibration 9 Erasing 10 CONNECTIONS CONTROLS DEVICES AND APPLICAT...

Page 3: ...time of dry run 6 sec or this can be set manually Recovery time of over load 30 min Recovery time of under over voltage 5 min Recovery time of dry run 30 min or this can be set manually Trip voltage...

Page 4: ...following tools You also can choose the right tools according to your own experience INSTALLATION CONTROLLER COMPONENTS LCD Screen Voltage v M Minute Second S H Hour Ampere A The parameter configurati...

Page 5: ...paired and installed back Setting of parameters calibration of unit according to the connected load X X X X X X b Control terminals for connecting probes or float switches Press the MODE key to switch...

Page 6: ...will start flashing on the LCD screen For re calibration follow the instruction as given in CALIBRATION section ERASING NOTE For all applications connect the NO contact of float switch in down positi...

Page 7: ...ys RUN indicating pump is running Stop Condition If the water level in the OH tank rises and Float switch in OH tank is in up position the pump stops LCD screen displays FULL indicating OH tank is ful...

Page 8: ...r level in the pit tank rises and the float switch is in up position the pump starts LCD screen displays RUN indicating pump is running Stop condition If the water level in the pit tank decreases and...

Page 9: ...LCD screen displays NO WATER that means there is no water in the source tank and can lead to a dry run situation If the Pressure in the line is equal to or above the cut out pressure setting on the p...

Page 10: ...signal from sensor float switch or pressure switch The controller can memorize hours the pump has run so it is very convenient for the pump users to analyse pump running condition and perform maintena...

Page 11: ...istance like mine water tower across railway road and bridge etc users can adopt RS485 extender Technical Parameters The following chart shows main technical parameters of communication between the pu...

Page 12: ...and 5 minutes respectively Liquid level in the borewell or lower tank is below pump intake pump stop running Liquid level in the lower water tank water well is below lower sensor probe float switch in...

Page 13: ...ated voltage pump is in over voltage protection state Check the power supply at source Control unit will attempt to restart the pump every 5 minutes until line voltage is restored to normal Flashing o...

Page 14: ...Note Float Pressure Switch should be ordered separately Abbreviation 1 OH Overhead 2 UG Underground 3 NO Normally Open 4 DOL Direct online start 5 COM Common 26...

Reviews: