En
gl
is
h (
G
B)
12
1)
Data is based on measurements with water
2)
Maximum suction lift: 1 m, dosing capacity reduced (approx. 30 %)
3)
Length of suction line: 1.5 m, length of discharge line: 10 m (at max. viscosity)
Mechanical
data
Max. inlet pressure, suction side
[bar]
2
Max. viscosity with spring-loaded valves
2)
[mPas]
(= cP)
600
500
Max. viscosity without spring-loaded valves
2)
[mPas]
(= cP)
50
Min. internal hose/pipe diameter
suction/discharge side
1), 3)
[mm]
4
6
Min. internal hose/pipe diameter
suction/discharge side (high viscosity)
3)
[mm]
9
Min./Max. liquid temperature
[°C]
-10/45
Min./Max. ambient temperature
[°C]
0/45
Min./Max. storage temperature
[°C]
-20/70
Max. relative humidity (non-condensing)
[%]
96
Max. altitude above sea level
[m]
2000
Electrical
data
Voltage
[V]
100-240 V, - 10 %/+ 10 %,
50/60 Hz
Length of mains cable
[m]
1.5
Max. inrush current for 2 ms (100 V)
[A]
8
Max. inrush current for 2 ms (230 V)
[A]
25
Max. power consumption P
1
[W]
19
Enclosure class
IP65, Nema 4X
Electrical safety class
II
Pollution degree
2
Signal
input
Max. load for level input
12 V, 5 mA
Max. load for pulse input
12 V, 5 mA
Max. load for external stop input
12 V, 5 mA
Min. pulse length
[ms]
5
Max. pulse frequency
[Hz]
100
Max. resistance in level/pulse circuit
[
Ω
]
1000
Signal
output
Max. ohmic load on relay output
[A]
0.5
Max. voltage on relay output
[V]
30 VDC/30 VAC
Weight/size
Weight (PVC, PP, PVDF)
[kg]
2.4
Weight (stainless steel)
[kg]
3.2
Diaphragm diameter
[mm]
44
50
Sound
pressure
Max. sound pressure level
[dB(A)]
60
Approvals
CE, CB, CSA-US, NSF61, GOST, C-Tick
Data
6-10
15-4