English (GB)
11
2.7 Product overview
Fig. 2
Overview
3. Technical data / Dimensions
3.1 Technical data
TM04
1
1
4
9
5
11
1
Mains connection
Mechanical lock
Mounting plate
Drain opening in
case of diaphragm
breakage
Connection,
deaeration hose
Valve, discharge side
Deaeration valve
(Section
5.3
)
Valve, suction side
Signal
inputs/outputs *
(Section
4.3
)
Keys* and status LED
Dosing head
* only control variant DDE-PR/P
Operating elements
(Section
6.1
)
Capacity
adjustment knob
Data
6-10
15-4
Mechanical
data
Turndown ratio (setting range)
[1:X]
1000
1000
Max. dosing capacity
[l/h]
6.0
15.0
[gph]
1.5
4.0
Min. dosing capacity
[l/h]
0.006
0.015
[gph]
0.0015
0.0040
Max. operating pressure
[bar]
10
4
[psi]
150
60
Max. stroke frequency
[strokes/min]
140
180
Stroke volume
[ml]
0.81
1.58
Accuracy of repeatability
[%]
± 5
Max. suction lift during operation
1)
[m]
6
Max. suction lift when priming with wet valves
1)
[m]
2
3
Min. pressure difference between suction and
discharge side
[bar]
1