8
English (US)
6. Technical data
6.1 Approvals
Warning
For indoor potable water use only
System
Max storage temperature:
170 °F (76 °C)
Ambient temperature:
-4 to +175 °F (-20 to +80 °C)
System type:
Open - residential potable
UP15-10SU7P/TLC
Flow range:
0 - 6.3 gpm (0 - 1.4 m
3
/h)
Head range:
0 - 5.1 ft (0 - 1.5 m)
Motor:
Single phase, 60 Hz
Max. working pressure:
145 psi (10 bar)
Min. working pressure:
Minimum system pressure
Max. liquid temperature:
150 °F (66 °C)
Min. liquid temperature:
36 °F (2 °C)
Connection:
3/4" M x 3/4" F NPT
Thermal bypass valve
Connections:
1/2" NPSM
Timer
Supply voltage:
115-120 VAC
Contact rating:
16 amps
Three manual switch
modes
ON
Continuous pumping, 24 hrs/day;
7 days/week
TIMER
Controlled by programming tab
settings
OFF
No pumping
Programming tabs
15-minute increments
Flex hoses
Connections:
1/2" FNPS x 1/2" FNPS x 12"
ANSI/NSF61
ANSI/NSF372
Comfort Pump
Comfort Valve
UL/cUL
(Electrical Safety)
Comfort Pump
IAPMO (UPC)
Comfort Pump with
Comfort Valve
(Comfort System)
IAPMO (cUPC)
Comfort Valve
ANSI/NSF372