background image

En
gli
s

h (
U

S

)

4

2. Discharge assembly

– 4" x discharge size pipe
– Discharge size union
– Discharge size nipple
– Discharge size tee fitting

3. Suction assembly

– Suction size pipe nipple
– Suction size check valve

4. These installation and operating instructions

5. Kit assembly

5.1 Discharge assembly

1. Remove the CME pump from the box and place on workbench 

or work area.

2. Wrap 3 to 4 turns of Teflon® tape on all of the male threads

of the discharge pipe fittings.

3. Thread the 4-inch by discharge sized pipe into the discharge 

of the pump. Thread the union, then the 2-inch by discharge 
sized pipe and tee onto the discharge pipe so that tee is on its 
side and the horizontal opening faces away from the terminal 
box.

Fig. 2

Discharge assembly

5.2 Assemble the tank/transducer manifold

1. Wrap 3 to 4 turns of Teflon tape on all of the male threads of 

the pipe fittings and the pressure transducer. It is not
necessary to wrap Teflon tape on the tank threads.

2. Thread the 1/2” NPT plug into a port on the cross fitting until 

hand tight. This port can be any of the four ports of the cross 
fitting. See fig. 3.

Fig. 3

Threading plug into cross fitting

3. Thread the 1/4” to 1/2" NPT bushing into one of the ports next 

to the plug from Step 2 in the cross fitting. This will be opposite 
of where the tank will be positioned. See fig. 4. Tighten until 
wrench tight.

Fig. 4

Threading bushing into cross fitting next to plug

4. Thread the pressure transducer into the 1/4" NPT port of the 

bushing that you installed in Step 3 (this is before wiring the 
transducer to the terminal box); see fig. 5. Tighten until wrench 
tight.

Fig. 5

Threading pressure transducer into bushing

5. Thread the 1/2” NPT pipe nipple into the port on the cross

fitting opposite of the 1/2” NPT plug from Step 2. Tighten 
wrench tight; see fig. 6.

6. Thread the 1/2” to discharge size NPT bushing(s) onto 1/2” 

NPT pipe nipple. Tighten wrench tight; see fig. 6.

Fig. 6

Installing pipe nipple into cross fitting and bushing onto 
pipe nipple

Note

Note

 If you purchased a completed CME-Plus from 
the factory, a discharge pipe and union is 
already installed in the pump discharge and the 
tank/transducer manifold is already assembled. 
Attach the union assembly and then skip to
section 5.3 Attach the tank.

T

M

05

 0652

 131

1

T

M

05 06

53 13

11

T

M

05

 0

6

54

 1

3

11

T

M

05

 0655

 131

1

T

M

05 06

56 13

11

CME Plus Kit Assembly I&O.book  Page 4  Thursday, April 7, 2011  4:41 PM

Summary of Contents for CME-Plus

Page 1: ...GRUNDFOS INSTRUCTIONS CME Plus Kit assembly Installation and operating instructions ...

Page 2: ...2 ...

Page 3: ...ages and some jurisdictions do not allow limit actions on how long implied warranties may last Therefore the above limitations or exclusions may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from jurisdiction to jurisdiction 2 Symbols used in this document 3 General The Grundfos CME Plus system is for the pumping of clean thin and non ...

Page 4: ... four ports of the cross fitting See fig 3 Fig 3 Threading plug into cross fitting 3 Thread the 1 4 to 1 2 NPT bushing into one of the ports next to the plug from Step 2 in the cross fitting This will be opposite of where the tank will be positioned See fig 4 Tighten until wrench tight Fig 4 Threading bushing into cross fitting next to plug 4 Thread the pressure transducer into the 1 4 NPT port of...

Page 5: ...bar or 0 145 psi 0 10 bar STOP FUNCTION Active CONTROL MODE Controlled 6 2 Perform functional test Start the pump and perform the following functional test including monitoring for leaks and watching for any obvious problems 1 Reduce the setpoint to the second LED light from the bottom on the motor control panel by pressing the DOWN arrow as many times as necessary 2 Slowly close the discharge lin...

Page 6: ...6 ...

Page 7: ...27 3400 Telefax 1 913 227 3500 Canada GRUNDFOS Canada Inc 2941 Brighton Road Oakville Ontario L6H 6C9 Phone 1 905 829 9533 Telefax 1 905 829 9512 México Bombas GRUNDFOS de México S A de C V Boulevard TLC No 15 Parque Industrial Stiva Aeropuerto Apodaca N L C P 66600 Phone 52 81 8144 4000 Telefax 52 81 8144 4010 ...

Page 8: ...akes it possible Innovation is the essence The name Grundfos the Grundfos logo and the payoff Be Think Innovate are registrated trademarks owned by Grundfos Management A S or Grundfos A S Denmark All rights reserved worldwide L CM TL 004 0411 US 2011 Grundfos Pumps Corp ...

Reviews: