2. Discharge assembly
– 4" x discharge size pipe
– Discharge size union
– Discharge size nipple
– Discharge size tee fitting
3. Suction assembly
– Suction size pipe nipple
– Suction size check valve
4. These installation and operating instructions
5. Kit assembly
5.1 Discharge assembly
1. Remove the CME pump from the box and place on workbench
or work area.
2. Wrap 3 to 4 turns of Teflon® tape on all of the male threads
of the discharge pipe fittings.
3. Thread the 4-inch by discharge sized pipe into the discharge
of the pump. Thread the union, then the 2-inch by discharge
sized pipe and tee onto the discharge pipe so that tee is on its
side and the horizontal opening faces away from the terminal
box.
Fig. 2
Discharge assembly
5.2 Assemble the tank/transducer manifold
1. Wrap 3 to 4 turns of Teflon tape on all of the male threads of
the pipe fittings and the pressure transducer. It is not
necessary to wrap Teflon tape on the tank threads.
2. Thread the 1/2” NPT plug into a port on the cross fitting until
hand tight. This port can be any of the four ports of the cross
fitting. See fig. 3.
Fig. 3
Threading plug into cross fitting
3. Thread the 1/4” to 1/2" NPT bushing into one of the ports next
to the plug from Step 2 in the cross fitting. This will be opposite
of where the tank will be positioned. See fig. 4. Tighten until
wrench tight.
Fig. 4
Threading bushing into cross fitting next to plug
4. Thread the pressure transducer into the 1/4" NPT port of the
bushing that you installed in Step 3 (this is before wiring the
transducer to the terminal box); see fig. 5. Tighten until wrench
tight.
Fig. 5
Threading pressure transducer into bushing
5. Thread the 1/2” NPT pipe nipple into the port on the cross
fitting opposite of the 1/2” NPT plug from Step 2. Tighten
wrench tight; see fig. 6.
6. Thread the 1/2” to discharge size NPT bushing(s) onto 1/2”
NPT pipe nipple. Tighten wrench tight; see fig. 6.
Fig. 6
Installing pipe nipple into cross fitting and bushing onto
pipe nipple
Note
Note
If you purchased a completed CME-Plus from
the factory, a discharge pipe and union is
already installed in the pump discharge and the
tank/transducer manifold is already assembled.
Attach the union assembly and then skip to
section 5.3 Attach the tank.