•
Ranges: 0-20 and 4-20 mADC.
•
Maximum load between AO and GND: 500 Ω.
•
Open-circuit protection: Yes.
Tolerance: 0-4 % of full scale, maximum-point coverage.
Screened cable: 0.5 - 1.5 mm
2
/ 28-16 AWG.
Maximum cable length: 500 m.
Pt100 or Pt1000 inputs (Pt)
Temperature range:
•
Minimum -50 °C (80 Ω/803 Ω).
•
Maximum 204 °C (177 Ω/1773 Ω).
Measurement tolerance: ±1.5 °C
Measurement resolution: less than 0.3 °C.
Automatic range detection (Pt100 or Pt1000): Yes.
Sensor fault alarm: Yes.
Screened cable: 0.5 - 1.5 mm
2
/ 28-16 AWG.
Use Pt100 for short wires.
Use Pt1000 for long wires.
LiqTec sensor inputs
Use a Grundfos LiqTec sensor only.
Screened cable: 0.5 - 1.5 mm
2
/ 28-16 AWG.
Grundfos Digital Sensor input and output (GDS)
Use Grundfos Digital Sensor only.
Power supplies, +5 V, +24 V
+5 V
•
Output voltage: 5 VDC - 5 % to + 5 %.
•
Maximum current: 50 mADC, sourcing only.
•
Overload protection: Yes.
+24 V
•
Output voltage: 24 VDC - 5 % to + 5 %.
•
Maximum current: 60 mADC, sourcing only.
•
Overload protection: Yes.
Digital outputs, relays
Potential-free changeover contacts.
Minimum contact load when in use: 5 VDC, 10 mA.
Screened cable: 0.5 - 2.5 mm
2
/ 28-12 AWG.
Maximum cable length: 500 m.
Bus input
Grundfos GENIbus protocol, RS-485.
Screened 3-core cable: 0.5 - 1.5 mm
2
/ 28-16 AWG.
Maximum cable length: 500 m.
13. Disposing of the product
This product or parts of it must be disposed of in an environmentally sound way.
1.
Use the public or private waste collection service.
2.
If this is not possible, contact the nearest Grundfos company or service workshop.
3.
Dispose of the waste battery through the national collective schemes. If in doubt, contact your local Grundfos company.
The crossed-out wheelie bin symbol on a product means that it must be disposed of separately from household waste. When a
product marked with this symbol reaches its end of life, take it to a collection point designated by the local waste disposal
authorities. The separate collection and recycling of such products will help protect the environment and human health.
See also end-of-life information at
www.grundfos.com/product-recycling
.
30
English (GB)