Performance curves
Technical data
S pumps, range 58
39
Electrical data
Note:
Enclosure class: IP68
Pump data
* With 50 ft (15 m) cable
Pump type
P1
[kW]
P2
[hp]
No. of
poles
RPM
Starting
method
I
N
I
start
η
motor
[%]
Cos
ϕ
Moment of
inertia
[lbft2 (kgm
2
]
Breakdown
torque M
max
[lbf*ft (Nm)]
[A]
[A]
1/2
3/4
1/1
1/2
3/4
1/1
S1.40.A50.420.4.58M
35
42
4
1749
Y/D
52
284
89
90
88
0.75
0.82
0.85
3. 56 (0.15 )
286.9 (389)
Pump type
Max. solids size
Max. installation depth
Weight *
[inch (mm)]
[feet (m)]
[lbs (kg)]
S1.40.A50.420.4.58M.S
4 (100)
66 (20)
992 (450)
S1.40.A50.420.4.58M.C
4 (100)
66 (20)
1102 (500)
S1.40.A50.420.4.58M.D
4 (100)
66 (20)
1190 (540)
S1.40.A50.420.4.58M.H
4 (100)
66 (20)
1190 (540)
S_Range_58-60Hz.book Page 39 Thursday, July 8, 2010 2:30 PM