Technical specifications
64 | 72
B
A
_
T
D3
-A
M
0
0
1
e
n
_
0
1
4
_
M
X
A
.d
o
cx
Dimensions and weights
GENO-backwash filter MXA with flange connection
Nominal connection diameter
DN 65
DN 80
DN 100
B
Installation length without counter-flanges;
flanges PN 16 acc. to DIN EN 1092-1
[mm]
220
250
250
C
Min. distance to wall
[mm]
115
125
125
D
Overall height above centre of connection
[mm]
233
243
243
E
Overall height up to centre of connection
[mm]
212
302
302
F
Total height
[mm]
445
545
545
G
Clearance above upper edge of filter
[mm]
130
H
Clearance required for the replacement of
the filter element
[mm]
min. 100
optimum from 215
min. 100
optimum from 315
I
Bolt circle diameter of flange
[mm]
145
160
180
J
Max. sealing surface
[mm]
122
140
158
K
Number of M 16 screws
[pcs]
4
8
8
Length of cable for differential pressure sensor
[mm]
1500
Length of cable for drive unit
[mm]
1500
Length of mains cable
[mm]
1500
Empty weight with control unit GENO-RS-tronic,
approx.
[kg]
14.8
19
20
Performance data
Flow rate at Δp 0.2 (0.5) bar
[m
3
/h]
30 (47)
60 (96.5)
60 (98)
K
V
value
[m
3
/h]
69
124
138
Pore size
[µm]
100
Largest/smallest pore size
[µm]
110/90
Nominal pressure
PN 16
Minimum flow pressure
[bar]
2
Operating pressure at max. water temperature
[bar/°C]
10/90
Differential pressure release
[bar]
0.4 - 0.5
General
DVGW registration number
NW-9301BO0194
Max. water temperature
[°C]
90
Max. ambient temperature
[°C]
5 - 40
Order no.
107 470
107 475
107 480
Connection data
Rated voltage range
[V]
230
Rated frequency
[Hz]
50 - 60
Power input (standby)
[W]
19
Power input (operation = max))
[W]
26
Protection/protection class
IP 54/