Operating Instructions: LUB‐M
20
Tim
e cont
ro
l
5.6
Change PIN , factory setting PIN: 000 (Master PIN see Service)
In the menu point „PIN“ you can change the PIN for the access of the PRO-Menues.
Example: Change PIN to 222
The new PIN is saved.
5.7
Change Feedback (Pump function control)
Feedback = Pump function control:
During the function of the pump (about 7 s) the output signal at PIN 4 is switching from High (+
20...30 VDC) to Low (0 V). By counting the signals of the pump function control there is a possibility to estimate the delivered quantity of
lubricant and the remaining quantity in the lubricant reservoir (delivery rate per cycle =0,15 cm³).
Factory setting:
F 1 = Feedback “on”
Alternative:
F 0 = Feedback “off”