background image

LIT-258       PAGE 2 of 4

Magnum

®

 Handpiece 

PARTS LIST

 

 

 

 

        

     

#004-940

REASSEMBLY NOTE

There is an O-ring inside the knob that makes getting the handpiece body to 

thread a little difficult when reassembling. Use a very small amount of synthetic 

lube or non-stick grease and create a thin film around the OUTSIDE of the 

handpiece body between the threads and the end (FIG. 8). See “Adjusting 

The Handpiece” on p. 1 of this literature sheet for adjusting graver and hose 

position.

QUICK CHANGE HOLDER HINT

Synthetic Lube or non-stick grease on the shaft of a quick change holder will 

make them easier to slip in and out.

NOTE: Do NOT use 

petroleum based oils - 

USE ONLY Synthetic 

oils. Fossil oils can 

damage the O-Rings.

PART NO. DESCRIPTION

002-127  O-RING

002-605  HEX WRENCH, 5/64" 

004-803  QC HOLDER

022-072  BARBED FITTING FOR 1/4" X .040" WALL TUBING

022-946  O-RING

022-947  O-RING 1mm X 12.5mm

022-948  O-RING 70 DUROMETER

044-020  ANVIL

044-021  THREADED RETAINER

044-022  TOOL RECEIVER

044-023  SPRING COMPRESSION

044-507  PISTON

044-025  HANDPIECE BARREL

044-026  LOCK NUT

044-028  TUBING, PU CLR 0.250" O.D. 0.160" I.D

044-029  TUBING, PU CLR 0.250" O.D. 0.170" I.D. 

044-030  PALM KNOB

044-031  HOSE RETAINER

Very Light 

synthetic grease film

FIG. 8

Hollow end

Very Light 

synthetic grease film

Optional upgrades:

#044-507 

Tungsten Piston

#044-163

Shortened Barrel

Summary of Contents for Magnum

Page 1: ...piston If you notice a loss of power or erratic performance first check if the receiver chuck is tight in the handpiece body Using a crescent wrench or pliers with a graver inserted in the QC Holder gently tighten receiver clockwise FIG 4 If erratic performance continues then disassemble and clean the handpiece To disassemble the handpiece use the crescent wrench or pliers to grip the graver FIG 4...

Page 2: ... will make them easier to slip in and out NOTE Do NOT use petroleum based oils USE ONLY Synthetic oils Fossil oils can damage the O Rings PART NO DESCRIPTION 002 127 O RING 002 605 HEX WRENCH 5 64 004 803 QC HOLDER 022 072 BARBED FITTING FOR 1 4 X 040 WALL TUBING 022 946 O RING 022 947 O RING 1mm X 12 5mm 022 948 O RING 70 DUROMETER 044 020 ANVIL 044 021 THREADED RETAINER 044 022 TOOL RECEIVER 044...

Page 3: ...4 031 1 HOSE RETAINER 044 110 D1 3 PALM PAD E2 04 044 110 E2 06 3 PALM PAD E2 06 044 110 E2 08 3 PALM PAD E2 08 044 110 E2 10 3 PALM PAD E2 10 044 126 1 FITTING 0 094 O D 0 063 I D x 0 35 044 130 1 TUBING PU CLR 0 125 O D 0 063 I D 044 162SS 1 PALM KNOB MAGNUM 044 204 2 0 500 DIA BLACK SHRINK TUBING 044 219 1 INLET INSERT FOR MAGNUM AT KNOBS 044 231 1 BRAIDED SLEEVE 0 375 O D NYLON PART NO DESCRIP...

Page 4: ...th a lower number palm pad installed Initially palm pads can be stiff This affects the feel and control Stiffness may be reduced naturally with a few hours of use To reduce stiffness quickly bend and twist the control flap to soften When the preferred softness is nearly reached stop and test frequently to adjust until desired responsiveness is attained The rubber control flap can be formed for a custom ...

Reviews: