CONFIGURATION
STEP 3 : CONNECT YOUR EQUIPMENT (120V 15Amps MAX)
Connect your equipment into the 120V outlet on the front of your controller, set your values and
control mode, then you’re set!
•
FAN (to COOL, COOL & DEHUMIDIFY or DEHUMIDIFY)
•
HUMIDIFIER (to HUMIDIFY)
•
DEHUMIDIFIER (to DEHUMIDIFY)
•
HEATER (to HEAT), 1000W heater recommended to maximize
product service life.
DURING THE NORMAL OPERATION, LED or BAR INDICATORS
WILL BLINK IN THESE SPECIAL CONDITIONS:
BLINKING INDICATORS (only one blinking at a time):
The blinking indicator tells you which of temperature or humidity is currently shown and which of
day or night period is being detected by the light sensor.
E.g. A Blinking Humidity Sun Icon stands for “Display currently shows Humidity value” and
“The controller currently works during a Day Period”.
BLINKING TEMPERATURE OR HUMIDITY BARS:
The temperature or humidity values are indicated by the upper 15 bars of display.
•
Temperature reading: TOP BAR is blinking when temperature is above 104°F / 40°C.
BOTTOM BAR (of 15) is blinking when temperature is below 48°F / 9°C. Otherwise,
temperature is within these 2 limits.
•
Humidity reading: BOTTOM BAR is blinking when humidity is below 10%. Humidity
above 100% is impossible, TOP BAR will never blink.
•
Temp sensor failure: both TEMPERATURE TOP and BOTTOM BARS are blinking when
the temp sensor reading is invalid. The Output will be held OFF if the control mode is using
this sensor. Unit may need to be repaired.
•
Humidity sensor failure: both HUMIDITY TOP and BOTTOM BARS are blinking when
the humidity sensor reading is invalid. The Output will be held OFF if the control mode is
using this sensor. Unit may need to be repaired.