COMPLETE TROUBLESHOOTING GUIDE
STEP
HANDLING AND TEST
DESCRIPTIONS
EXPECTED RESULTS
6
•
Click knob once to resume
normal operation.
DAY ON time or DAY OFF time
indicator is BLINKING,
meaning ON or OFF time
countdown is underway.
The unit will cycle 10 seconds
ON followed by 1 minute OFF.
Observe one complete ON-
OFF cycle and verify ON and
OFF times.
LOAD must be ON when
either DAY ON time or NIGHT
ON time indicator is lit.
7
•
Cover the
Light Sensor
completely with the palm of
your hand or black electrical
tape (a single finger will NOT
cover the sensor
appropriately) and wait 8
seconds until the NIGHT
condition is met.
DAY OFF time and DAY ON
time indicators (i.e. both
"
Sun
"
icons) turn OFF.
NIGHT OFF time indicator
starts BLINKING and 4th bar
turns ON.
8
•
Uncover the
Light Sensor
and
wait 8 sec until DAY condition
is met.
4th bar turns OFF.
NIGHT OFF time and NIGHT
ON time indicators (i.e. both
"
Moon
"
icons) turn OFF.
DAY ON time indicator starts
BLINKING and 2nd bar turns
ON.
COMPLETE TROUBLESHOOTING GUIDE
12
Summary of Contents for Cyclestat-3 CY3
Page 1: ...www grozonecontrol com USER GUIDE CY3 Digital Timer...
Page 15: ...NOTE 15...
Page 16: ......
Page 17: ...GUIDE DE L USAGER CY3 S quenceur num rique www grozonecontrol com...
Page 31: ...NOTE 15...
Page 32: ...Rev 4 0 www grozonecontrol com...