TROUBLESHOOTING

PROBLEM

CAUSE

SOLUTION

Pump does not dispense grease

Air pockets/trapped air inside grease

Follow Priming steps

Follower plate got stuck

Open the drum cover and resettle the follower plate.

Very thick grease mainly in winter

Warm the grease bucket a little

Contaminants causing blockage

Open the drum cover and remove  the blockage

Grease leaks from top of the Pump head

Worn piston O-ring

Replace the O-ring.

CONNECTING THE GREASE COUPLER

The Grease Coupler provided at the end of the nozzle has jaw 

type construction. The coupler jaws will snap on to a grease 

fitting and maintain a tight fit.

1. 

When connecting the coupler to a grease fitting, press the  

coupler straight on to  the grease fitting to form a snug 

fit.

2.  Once greasing is completed, slightly tilt the coupler, twist  

and pull back.

3.  The tilt and twist action will allow easy removal of the  

coupler from the grease fitting.

To engage push 
straight on the 
grease nipple

To remove Tilt, 
Twist & Pull

CAUTIONS

1. 

Do not point the discharge nozzle towards yourself or 

anyone as there is a potential hazard for injection into the 

skin or eyes.

2.  Before operating the pump check the hose for signs of 

wear, leaks or loose connections. If hose is weak, worn or 

damaged, replace the hose immediately.

3.  In case of an accident, immediately seek medical attention.  

Do not try to treat the injury yourself.

Reviews: