Growatt ShineVision Operation Manual Download Page 3

Product Overview

 

ShineVision,  which  consists  of  a  power  monitor  and  a  number  of  transmitters,  can 
achieve 1 to 6 monitoring modes. The transmitters transmit the power data collected 
from  a  photovoltaic  inverter  to  the  monitor  and  display  the  data  onto  the  monitor 
screen,  as  along  as  data  of  generated  energy,  the  gross  generated  energy  and  the 
generation  income  obtained  from  the  above-mentioned  data  through  some  simple 
calculations.  We  can  also  see  3-phase  AC  voltage,  two-way  PV  voltage,  indoor 
temperature, date and time, as well as CO2 emissions.

 

2

Basic Operations and Display of Functions 

2.1 Check of software version and clear

Insert power supply (or batteries) after pressing “up” and “down” keys concurrently, 
LCD  will  display  3  seconds  in  full  screen  as  shown  in  Figure  2.  The  red  LED  light 
flashes quickly twice 3 seconds later (0.5 second per time), then release the “up” and 
“down” keys, LED light will be on for a long time, LCD will show the version No. of 
the  software  as  shown  in  Figure  3.  LED  light  will  turn  off  3  seconds  later,  and  LCD 
resets  to  the  default  interface  as  shown  in  Figure  4.  The  relevant  information  has 
been cleared.

Note:

 Factory default date: 01/01/2011 (dd/mm/yy), default time: 00:00.

Figure 2

Figure 3

Figure 4

 

 

 

Notes  :

  Power  up  the  monitor  via  the  power  adapter,  which  is  delivered  in  the 

package box. But for convenience, sometimes it’s available to use batteries.

Figure 1 Power Monitor and Transmitter

Overview

2.2 Code-matching operation

Before code-matching operation please connect the transmitters firmly to inverters 
via the RS232 port (figure5).  Detailed information refers to the next paragraph. 

Figure 5 Connect the transmitter to inverter 

Summary of Contents for ShineVision

Page 1: ...ENERGY CO LTD No 12 Building Xicheng Industrial Zone Bao an District Shenzhen P R China 86 755 2747 1900 86 755 2749 1460 service ginverter com www ginverter com T F E W Operation Manual ShineVision G...

Page 2: ...hing operation 2 3 1 Currency symbol setting 2 3 2 Income coefficient setting 2 3 Basic Setting 2 3 3 CO2 coefficient setting 2 3 4 Date setting 2 3 5 Time setting 2 3 6 Temperature unit setting 2 3 7...

Page 3: ...3 seconds in full screen as shown in Figure 2 The red LED light flashes quickly twice 3 seconds later 0 5 second per time then release the up and down keys LED light will be on for a long time LCD wil...

Page 4: ...once the codes are successfully matched Figure 6 Figure 7 Figure 8 2 3 Basic Setting In the default interface press OK key for quite a while 3 seconds later the red LED flashes quickly twice and then...

Page 5: ...current system time Figure 14 Figure 15 Figure 16 after adjustment then the 6 of 0 163 will flash press Up or Down to adjust its value ranging from 0 to 9 and press OK to confirm after adjustment then...

Page 6: ...current temperature symbol And now the symbol stops flashing and the interface is restored to the status as shown in Figure 9 then flashes If there is no need to set temperature unit press Down to ent...

Page 7: ...igure 17 to 22 Figure 26 There are two modes in the third line one showing the generated energy generation revenue and CO2 emissions in the month and the other showing the total generated energy total...

Page 8: ...display is shown as Figure 28 to 30 after entering all channels The figures show the data of CH 01 channel the data of other channels are much similar and the only difference is that clock areas show...