![Ground Zero RADIOACTIVE Series Owner'S Manual Download Page 8](http://html.mh-extra.com/html/ground-zero/radioactive-series/radioactive-series_owners-manual_2270060008.webp)
Specifications
Model
GZRA MICRO ONE
Type
1 Channel Class D
RMS Power @ 4
Ω
CEA Standard CEA-2006-A
1 x 220 W (1% THD+N)
1 x 270 W (10% THD+N)
RMS Power @ 2
Ω
CEA Standard CEA-2006-A
1 x 350 W (1% THD+N)
1 x 400 W (10% THD+N)
Damping factor
> 100
Lowpass
40 Hz – 400 Hz
Subsonic filter
15 Hz – 25 Hz
Bass boost
0 ~ +12 dB (45 Hz)
Frequency response
15 Hz – 400 Hz (± 1 dB)
Input sensitivity
200 mV – 5 V (± 5%)
Bass remote control
Fuse
30A
Min Power and GND Wire
8 mm² / 8 AWG
Dimensions
W x H x L mm
75 x 44 x 190
Dimensions
W x H x L inch
2.95“ x 1.73“ x 7.48“
Trouble shooting guide
Symptoms
Check Points
Cure
No sound
Is the POWER LED illuminated?
Check fuses in amplifier.
Be sure remote lead is connected.
Check signal leads.
Check again control.
Check tuner/deck volume level.
Is the diagnostic LED
illuminated?
Check for speaker short or amplifier
overheating
Amp not switching on
No power to the amplifier
Check power wire or connections
No power to remote wire with
receiver on
Check connections to radio
No sound in one channel
Check speaker leads
Inspect for short circuit or an open connection
Check audio leads
Reverse left and right RCA inputs to determine
if it is occurring before the amp
Amp turning off at medium /
high volume
Check speaker load impedance
Check the nominal load impedance at the
amplifier is equal to or greater than 2 ohms.
(If you use an ohm meter to check speaker
resistance, please remember that DC
resistance and AC impedance may not be the
same.)
Protection LED is on
Temperature shut down
Turn radio volume down
Speaker wires short
Separate speaker wires and insulate