GroTech TEC 4 NG Operating Manual Download Page 3

 

Setup 

 

P 1-4  

By pressing the arrow key 

 or 

 you can choose the pump 1- 4, 5 – 8 or 9 – 12 for calibrating. 

 
Pressing the key 

↵↵

 to entert he sub menu 

 
 

 

 

 

 

 

Calibr. 

 

 

 

 

 

 

Pump 1 

Now hold the hose of the pump to be calibrated into the measuring cup.  
By pressing the key 

↵↵

 the selected pump starts and doses for 30 seconds. On the top right side the elapsed seconds are 

displayed. 
After the pump time has finished measure the pumped liquid quantity and set the determined quantity by pressing the 
arrow key 

 or 

  (first full ml, then 0,1 ml steps)

 

 

Set P1 

 

19.0 ml 

 

     (the „old“ set value is displayed – factory setting  is 19) 

By pressing the key 

↵↵

 the determined quantity is set and the pump is calibrated. 

(During the pump doses it could be stopped by the key 

 . and the calibration process is stopped without a change).  

The initial calibration should be done  after at least 1 week in operation and should be done again after this time.. 
Experience has shown that during this period, the pump power changes. Then the pump power remains largely stable. 
For new dosing pumps, additional modules rsp. pump

 

heads please note: after initial calibration should be done a 

recalibration every 4 – 6 weeks, as during this operating period, the hoses and rollers run in and the dosing quantity 
may change. Thereafter, the dosing rate remains generally stable. 
The dosing quantity can also vary over time as a functon of wear and pollution of the pump heads.  
Regular cleaning of the pump heads and motor shafts are indispensable. See Attendance/Maintenance.

 

 
Reset to supply condition / deletion of the complete programme 
  

By continuously pressing the key 

 and plugging in of the mains supply at the same time, all set values, 

  

except the time setting are deleted, afterwards the connected devices will be indicated (EP, AUX or  

  

NONE for no device) and all connected pumps will be switched on shortly one after the other. 

 
Finding out the software-status 
 

By pressing the arrow key 

↑↑↑↑

 and 

↓↓↓↓

  at the same time the software status is indicated, e.g. Ver 11. 

 

By pressing the key 

↵↵

 you leave the indication.   

 
Connection of extension modules: 
  

Please unplug mains supply of the basic device. 

  

Please cut free with a sharp knife the gap for the connection plug at the marked position at the rear side  

  

of the device.  

  

Connect the extension module with the attached connection cable with the basic device. The extension 

  

modules EP II and EP IV can be operated at both plug positions, other additional devices only at plug 

  

position 4-7. 

  

Please reconnect the basic device to the mains supply (Plug in mains supply) by using the provided  

 

AC/DC-adapter. 

  

The basic device now recognises whether it is an EP additional device or another additional device of 

    Messrs. GroTech and releases the part of programme to be used. 
 
Special case: Please connect to plug position 5-8 
      If an additional device is connected to plug position 5-8, the display indicates    

 

 

 

    

New 

Device 1 

 

By pressing the key 

↵↵

 the sub-menue is entered in order to programme pump 5-8 

 

(Please see above: programming of pumps/ adjustment of dosing quantity) 

 
  

If a different extension module has been connected to this plug position, the values will be set to 

  

0000 in the programme in order to avoid faulty dosings. 

 

 

 

  

The programming of the EP-devices should otherwise be done as described above. 

 

For programming of other additional devices of Messrs. GroTech, please see the  

  

operating manual of the corresponding devices ! 

 
How to put the TEC 4 NG into operation: 
1.

 

Please place the TEC 4 NG close to the aquarium, below the top most water level. In order to avoid uncontrolled running 
of liquids into the aquarium (in case of defect rubber hoses) that is good practice. 

2.

 

It is possible to change the direction of each of the pump heads to 90°, 180° or 270° (up, lateral and below). Therefore 
please press the two clips, which are positioned left and right beneath the rubber hose outlets, pull off the pump head, turn 
the pump head into the desired position and fix onto the driving shaft. Pump head is correctly installed after you heard 
„click“.  

3.

 

Please connect rubber hose (rubber hose for air 4/6 millimetre) with the inlets and outlets of each pump via provided 
connectors (inside of the box). Left rubber hose is pressure side and right rubber hose is suction side (to be seen if the 
outlets are in below position). 

Summary of Contents for TEC 4 NG

Page 1: ... 00 Now the hour value can be changed by pressing the arrow keys or When pressing the key the number of hours is increased Now please set the requested time hours i e 19 00 h By pressing the key the hour value is set and the cursor moves to minutes SetClock 19 00 Now the minutes can be set After having set the requested time press again key and the cursor moves to day SetDay MON Now the day can be...

Page 2: ...eased that much that a minimum dosing quantity of 0 5 ml per cycle is not fallen below By pressing again key the value of the cycles is set and the menue point is entered Start 00 00 Here the starting time of pump 1 can be set by pressing arrow key or In case of the pumps the starting minutes are fix and only the starting hour can be changed The individual pumps have a preset time increment of 5 m...

Page 3: ...ction of extension modules Please unplug mains supply of the basic device Please cut free with a sharp knife the gap for the connection plug at the marked position at the rear side of the device Connect the extension module with the attached connection cable with the basic device The extension modules EP II and EP IV can be operated at both plug positions other additional devices only at plug posi...

Page 4: ...upply Not to be used in humid rooms Please protect against water During installation please take care that the unit will not be in direct contact with current carrying cables devices We recommend a minimum distance of 20 cm to cables and electric electronic devices mainly also transformers power supply units etc in order to avoid malfunction of the device s electronic The TEC 4 NG must not plugged...

Reviews: