GroTech TEC 4 NG Operating Manual Download Page 1

TEC 4 NG                                                             

Software version V13

 

Operating Manual - please read carefully before putting into operation!           

 

 

Microprocessor-controlled dosing unit for automatically daily dosing of trace-element solutions. 
 
The basic device TEC 4 NG switches on and off 4 dosing pumps which are integrated in the housing and thus doses to the 
aquarium maximum 4 different trace-element solutions, whereby the daily dosing quantity of each pump of  1 – 1999 ml/day 
as well as the dosing frequency of 1 - 24 times (splitting of the adjusted dosing quantity) has to be adjusted.  
Also all pumps could be switched off by the day. 
 
With the additional modules EP II and/or EP IV (not included in the scope of supply), the device can dose up to 12 different 
liquids and quantities. 
The dosing pumps have self-suction-effect. Suction height 8 metre H

2

O pressure height 10 metre H

2

O. 

Dosing accuracy  uncalibrated 

±

 20 % over life-time. 

 
Menue structure: 
-SETUP CLOCK  

 

(setting the time rsp. correct the time

-MANUAL CONTROL 

(manually operating of pumps

-SETUP PROGRAM    

(programming of pumps / setting of dosing quantity) 

-CALIBRATION  

 

(calibrating of TEC 4 NG, EPII rsp. EPIV 

 
Programming: 
Setup clock (supply condition): 
 

After having plugged in the AC/DC-adapter (or after a longer period of interruption of mains supply), the device starts 

with the time indication 00:00. First of all, the current time should be set as follows: 
 
Setup of clock resp. correction of time 
 

By pressing the key 

 the main menue is entered. 

 

Press the arrow key 

↑↑↑↑

 or 

↓↓↓↓

 that often till you reach item SETUP CLOCK  

 

By pressing the key 

 the sub-menue is entered. 

SetClock 

00:00 

 

Now the hour value can be changed by pressing the arrow keys 

↑↑↑↑

 or 

↓↓↓↓

 . When pressing the key 

↑↑↑↑

  

      the number of hours is increased. 
      Now please set the requested time (hours) i.e. 19:00 h 
By pressing the key 

↵↵

 the hour value is set and the cursor moves to minutes. 

 

SetClock 

19:00 

 

Now the minutes can be set. 

      After having set the requested time, press again key 

↵↵

 and the cursor moves to day. 

 

SetDay 

MON 

 

 

Now the day can be set by pressing  the arrow key 

↑↑↑↑

 or 

↓↓↓↓

(MON=Monday / TUE=Tuesday / 

 

WED=Wednesday / THU=Thursday / FRI=Friday / SAT=Saturday / SUN=Sunday) 

 

After having set the requested day, press again the key 

↵↵

 and the set time and the day and are stored. 

 

In case of interruption of mains supply, the clock continues to run over up to 3 days. 

 
Manual control of the pumps: 
 

You have the possibility to control the individual pumps manually. That means you can control 

      the individual pumps separately for deaeration. 
 

By pressing the key 

 the main menue is entered 

 

Press the arrow key 

↑↑↑↑

 or 

↓↓↓↓

 that often till you reach item MANUAL CONTROL 

 

By pressing the key 

↵↵

 the sub-menue is entered  

 

Now Pump 1 is indicated on the display 

 

By pressing the key 

↵↵

 pump 1 starts dispensing. 

      Now with the arrow key

↑↑↑↑

 or 

↓↓↓↓

 other pumps can be chosen and the rubber hoses can be deaerated.  

      By pressing again the key 

 you leave the programme.  

 
Programming of pumps/ adjustment of dosing quantity: 
 

By pressing the key 

 the main menue is entered. 

 

Press the arrow key 

↑↑↑↑

 or 

↓↓↓↓

 that often till you reach item SETUP PROGRAM 

 

By pressing the key 

↵↵

 the sub-menue is entered. The display now indicates 

 

SETUP  

P 1-4 

 

By pressing the key 

 or 

 you can now choose the pumps 1-4 (integrated in the basic device),  

 

pumps 4-7 (additional module) or 8-11 (additional module). (Menue point pump 5-8 and/or 

 

pump 9-12 is indicated only if corresponding additional devices are connected) 

Summary of Contents for TEC 4 NG

Page 1: ... 00 Now the hour value can be changed by pressing the arrow keys or When pressing the key the number of hours is increased Now please set the requested time hours i e 19 00 h By pressing the key the hour value is set and the cursor moves to minutes SetClock 19 00 Now the minutes can be set After having set the requested time press again key and the cursor moves to day SetDay MON Now the day can be...

Page 2: ...eased that much that a minimum dosing quantity of 0 5 ml per cycle is not fallen below By pressing again key the value of the cycles is set and the menue point is entered Start 00 00 Here the starting time of pump 1 can be set by pressing arrow key or In case of the pumps the starting minutes are fix and only the starting hour can be changed The individual pumps have a preset time increment of 5 m...

Page 3: ...ction of extension modules Please unplug mains supply of the basic device Please cut free with a sharp knife the gap for the connection plug at the marked position at the rear side of the device Connect the extension module with the attached connection cable with the basic device The extension modules EP II and EP IV can be operated at both plug positions other additional devices only at plug posi...

Page 4: ...upply Not to be used in humid rooms Please protect against water During installation please take care that the unit will not be in direct contact with current carrying cables devices We recommend a minimum distance of 20 cm to cables and electric electronic devices mainly also transformers power supply units etc in order to avoid malfunction of the device s electronic The TEC 4 NG must not plugged...

Reviews: