![GroTech TEC 4 NG Operating Manual Download Page 1](http://html1.mh-extra.com/html/grotech/tec-4-ng/tec-4-ng_operating-manual_2269909001.webp)
TEC 4 NG
Software version V13
Operating Manual - please read carefully before putting into operation!
Microprocessor-controlled dosing unit for automatically daily dosing of trace-element solutions.
The basic device TEC 4 NG switches on and off 4 dosing pumps which are integrated in the housing and thus doses to the
aquarium maximum 4 different trace-element solutions, whereby the daily dosing quantity of each pump of 1 – 1999 ml/day
as well as the dosing frequency of 1 - 24 times (splitting of the adjusted dosing quantity) has to be adjusted.
Also all pumps could be switched off by the day.
With the additional modules EP II and/or EP IV (not included in the scope of supply), the device can dose up to 12 different
liquids and quantities.
The dosing pumps have self-suction-effect. Suction height 8 metre H
2
O pressure height 10 metre H
2
O.
Dosing accuracy uncalibrated
±
20 % over life-time.
Menue structure:
-SETUP CLOCK
(setting the time rsp. correct the time)
-MANUAL CONTROL
(manually operating of pumps)
-SETUP PROGRAM
(programming of pumps / setting of dosing quantity)
-CALIBRATION
(calibrating of TEC 4 NG, EPII rsp. EPIV
Programming:
Setup clock (supply condition):
After having plugged in the AC/DC-adapter (or after a longer period of interruption of mains supply), the device starts
with the time indication 00:00. First of all, the current time should be set as follows:
Setup of clock resp. correction of time
By pressing the key
←
←
←
←
the main menue is entered.
Press the arrow key
↑↑↑↑
or
↓↓↓↓
that often till you reach item SETUP CLOCK
By pressing the key
↵
the sub-menue is entered.
SetClock
00:00
Now the hour value can be changed by pressing the arrow keys
↑↑↑↑
or
↓↓↓↓
. When pressing the key
↑↑↑↑
the number of hours is increased.
Now please set the requested time (hours) i.e. 19:00 h
By pressing the key
↵
↵↵
↵
the hour value is set and the cursor moves to minutes.
SetClock
19:00
Now the minutes can be set.
After having set the requested time, press again key
↵
↵↵
↵
and the cursor moves to day.
SetDay
MON
Now the day can be set by pressing the arrow key
↑↑↑↑
or
↓↓↓↓
. (MON=Monday / TUE=Tuesday /
WED=Wednesday / THU=Thursday / FRI=Friday / SAT=Saturday / SUN=Sunday)
After having set the requested day, press again the key
↵
↵↵
↵
and the set time and the day and are stored.
In case of interruption of mains supply, the clock continues to run over up to 3 days.
Manual control of the pumps:
You have the possibility to control the individual pumps manually. That means you can control
the individual pumps separately for deaeration.
By pressing the key
←
←
←
←
the main menue is entered
Press the arrow key
↑↑↑↑
or
↓↓↓↓
that often till you reach item MANUAL CONTROL
By pressing the key
↵
↵↵
↵
the sub-menue is entered
Now Pump 1 is indicated on the display
By pressing the key
↵
↵↵
↵
pump 1 starts dispensing.
Now with the arrow key
↑↑↑↑
or
↓↓↓↓
other pumps can be chosen and the rubber hoses can be deaerated.
By pressing again the key
←
←
←
←
you leave the programme.
Programming of pumps/ adjustment of dosing quantity:
By pressing the key
←
←
←
←
the main menue is entered.
Press the arrow key
↑↑↑↑
or
↓↓↓↓
that often till you reach item SETUP PROGRAM
By pressing the key
↵
↵↵
↵
the sub-menue is entered. The display now indicates
SETUP
P 1-4
By pressing the key
↑
or
↓
you can now choose the pumps 1-4 (integrated in the basic device),
pumps 4-7 (additional module) or 8-11 (additional module). (Menue point pump 5-8 and/or
pump 9-12 is indicated only if corresponding additional devices are connected)