background image

1

English

Application 

Operation is possible in conjunction with:
• Pressurized storage heaters
• Thermally controlled instantaneous heaters
• Hydraulically controlled instantaneous heaters
Operation with low-pressure storage heaters (displacement 
water heaters) is 

not

 possible.

Specifications 

• Max. flow

  

- Spout

approx. 35 L/min or 9.2 gpm/60 psi

- Handshower

max. 9.3 L/min or 2.5 gpm/60 psi

• Flow pressure 

- min.

7.25 psi

- recommended

14.5 - 72.5 psi

- greater than 72.5 psi, fit with pressure reducing valves

• Max. operating pressure

145 psi

• Test pressure

232 psi

• Temperature 

- max. (hot water inlet)

176

°

F

Notes

• Installation of backflow protection must comply with local 

codes and regulations.

• An access panel must be provided for access to diverting 

unit and hose connections.

• Major pressure differences between cold and hot water 

supply should be avoided.

Installation

Layout dimensions to establish centers and proper clearences, 
see dimensional drawing on fold-out page I.

Fitting and connection

, see fold-out page II and III, Figs. [1] 

to [10].

The hot water supply should be connected on the left, the cold 
water supply on the right side.

Water must flow in the direction of the arrows cast into the 
body of the side valves and diverter.

Flush piping system prior and after installation of faucet 
thoroughly! 

Shut off cold and hot water supply.

I. Install side valves

,

 

see fold-out page II, Fig. [1].

II. Install spout

,

 

see Figs. [2] and [3].

III. Install diverter

,

 

see Fig. [4].

When screwing in (left-hand thread) the sleeve (A), make 
sure that the internal groove aligns with the position of the 
set screw (B).

IV.Install the hose guide and handshower

,

 

see Fig. [5].

V. Install hoses

,

 

see Figs. [6], [7] and [8].

Connection

Connect hoses (C) and (D) to the supply lines,

 

see Fig. [9].

Open cold and hot water supply and check connections 
for leakage.

VI.Install handles (E) and (F)

,

 

see fold-out page III, Fig. [10].

Operation

- Handles (E) and (F)

,

 

see fold-out page III, Fig. [11].

- Diverter (G)

Turning handles (E) and (F) releases the water supply.
Water will emerge from the bath inlet first.

Pull diverter knob

= flow is diverted from bath inlet 

to shower outlet

Press diverter knob

= flow is diverted from shower 

outlet to bath inlet

Flow is diverted automatically from shower outlet to bath inlet 
when the faucet is closed.

Maintenance

Inspect and clean all parts, replace as necessary and lubricate 
with special grease.

Shut off cold and hot water supply.

I. Cartridge

, see fold-out page III, Fig. [12].

Assemble in reverse order.

II. Spray hose and filter

, see fold-out page III, Fig. [13]. 

Secure the spray hose against slipping down again.

Assemble in reverse order.

III. Diverter

, see fold-out page III, Fig. [14].

Assemble in reverse order.

When screwing in (left-hand thread) the sleeve (A), make 
sure that the internal groove aligns with the position of the 
set screw (B).

IV.Flow control (13 922)

, see fold-out page I.

Assemble in reverse order.

Replacement parts

, see fold-out page I (* = Special 

accessories).

Care

Instructions for care of this faucet will be found in the Limited 
Warranty supplement.

Summary of Contents for Veris 19 363

Page 1: ...English 1 Français 2 Español 3 Design Quality Engineering GROHE Germany Veris Veris 96 841 131 ÄM 216932 03 10 19 363 ...

Page 2: ...I Please pass these instructions on to the end user of the fitting S v p remettre cette instruction à l utilisateur de la robinetterie Bitte diese Anleitung an den Benutzer der Armatur weitergeben ...

Page 3: ...II 32mm 3 50mm 1 3mm 100 360 2 7mm 32mm 50mm A B 4 6 29mm 24mm 19mm 29mm 29mm 27mm 7 13mm 30mm 19mm 29mm 24mm 29mm 24mm 8 32mm 13mm 13mm 8mm 5 24mm 24mm C D 9 ...

Page 4: ...see Figs 2 and 3 III Install diverter see Fig 4 When screwing in left hand thread the sleeve A make sure that the internal groove aligns with the position of the set screw B IV Install the hose guide and handshower see Fig 5 V Install hoses see Figs 6 7 and 8 Connection Connect hoses C and D to the supply lines see Fig 9 Open cold and hot water supply and check connections for leakage VI Install h...

Page 5: ...he la douille A veiller à ce que la rainure intérieure concorde avec la position de la tige filetée B IV Montage de la traversée de flexible et de la douchette voir fig 5 V Montage des flexibles voir fig 6 7 et 8 Raccordement Brancher les flexibles C et D aux conduites d alimentation voir fig 9 Ouvrir l arrivée d eau froide et d eau chaude et vérifier l étanchéité des raccordements VI Montage des ...

Page 6: ... ranura interior coincida con la posición del pasador roscado B IV Montaje del paso de tubo flexible y de la teleducha véase la fig 5 V Montaje de los tubos flexibles véanse las figs 6 7 y 8 Conexión Conectar los tubos flexibles C y D con los conductos de alimentación véase la fig 9 Abrir las llaves de paso del agua fría y del agua caliente y comprobar la estanqueidad de las conexiones VI Montaje ...

Page 7: ...III 12 17mm 45 888 45 887 13 14 32mm 17mm 7mm A B 10 E F 11 E F G ...

Page 8: ...uga Ontario Canada L5E 1E9 Technical Services Services Techniques Phone Tél 905 271 2929 Fax Télécopieur 905 271 9494 Grohe America Inc 241 Covington Drive Bloomingdale IL 60108 U S A Technical Services Phone 630 582 7711 Fax 630 582 7722 www grohe com ...

Reviews: