6
3. Disconnect plug-in connectors from the electronics
module (E) to the solenoid valve (D) and to the
transformer (F), see Fig. [19].
4. Remove screws (E2) and holder (E3), see Fig. [20].
5. Replace old electronics module (E4) and assemble new
electronics module in reverse order on plate (E),
see Fig. [20].
6. Connect solenoid valve (D) and battery box (F)
to electronics (E), see Fig. [6].
Assemble in reverse order.
Replacement parts,
see fold-out page I
(* = special accessories)
Care
For directions on the care of this fitting, refer to the
accompanying Care Instructions.
Fault/ cause/ remedy
Fault
Cause
Remedy
No flushing
• Water supply interrupted
- Open isolating valve in wall connection
box
• Filter in solenoid valve blocked
- Clean or replace filter,
see
Cleaning or replacing filter
• Plug-in connector without contact
- Attach plug-in connector
• The detection zone of the sensor system
is set too low/too high
- Increase/reduce detection zone using
remote control
(special accessories 36 206)
• Solenoid valve defective
- Replace solenoid valve,
see
Replacing solenoid valve
• Transformer faulty
- Replace transformer,
see
Replacing transformer
• Electronics defective (indicator
lamp not flashing or permanently on)
- Replace electronics,
see
Replacing the top plate
with electronics
Water flowing continuously
• Solenoid valve defective
- Replace solenoid valve,
see
Replacing solenoid valve
Undesired flushing
• The detection zone of the sensor system
is set too high
- An opposite object will be detected.
Reduce detection zone using remote
control (special accessories 36 206).
Flow volume too low
• Flow volume set too low
- Adjust flow volume,
see
Setting the flow volume
• Filter in solenoid valve blocked
- Clean or replace filter,
see
Cleaning or replacing filter
• Solenoid valve defective
- Replace solenoid valve,
see
Replacing solenoid valve
Flow volume too high
• Flow volume set too high
- Adjust flow volume,
see
Setting the flow volume
• Solenoid valve defective
- Replace solenoid valve,
see
Replacing solenoid valve
Summary of Contents for Tectron 37749
Page 7: ...III 19 E D F 20 E2 E E3 E4 18 F 1 2 17 G F 1 2 15 D1 D1 D 14 K 2 1 16 D E ...
Page 8: ......
Page 9: ......