Grohe Tectron 37749 Quick Start Manual Download Page 1

D

.....1

I

.....5

N

.....9

GR

.....13

TR

.....17

BG

.....21

RO

.....25

GB

.....2

NL

.....6

FIN

.....10

CZ

.....14

SK

.....18

EST

.....22

CN

.....26

F

.....3

S

.....7

PL

.....11

H

.....15

SLO

.....19

LV

.....23

RUS

.....27

E

.....4

DK

.....8

UAE

.....12

P

.....16

HR

.....20

LT

.....24

94.329.331/ÄM 203841/10.08

Tec

tron

Tectron

37 749

38 451

D

.......1

I

.....13

N

.....25

GR

.....37

TR

.....49

BG

.....61

RO

.....73

GB

.......4

NL

.....16

FIN

.....28

CZ

.....40

SK

.....52

EST

.....64

CN

.....76

F

.......7

S

.....19

PL

.....31

H

.....43

SLO

.....55

LV

.....67

RUS

.....79

E

.....10

DK

.....22

UAE

.....34

P

.....46

HR

.....58

LT

.....70

Design & Quality Engineering GROHE Germany

Summary of Contents for Tectron 37749

Page 1: ...19 LV 23 RUS 27 E 4 DK 8 UAE 12 P 16 HR 20 LT 24 94 329 331 ÄM 203841 10 08 Tectron Tectron 37 749 38 451 D 1 I 13 N 25 GR 37 TR 49 BG 61 RO 73 GB 4 NL 16 FIN 28 CZ 40 SK 52 EST 64 CN 76 F 7 S 19 PL 31 H 43 SLO 55 LV 67 RUS 79 E 10 DK 22 UAE 34 P 46 HR 58 LT 70 Design Quality Engineering GROHE Germany ...

Page 2: ... 749 Please pass these instructions on to the end user of the fitting S v p remettre cette instruction à l utilisateur de la robinetterie Bitte diese Anleitung an den Benutzer der Armatur weitergeben 38 451 ...

Page 3: ...II 1 A A1 1 2 H 5 s 2 3 B1 B 4 D1 D1 D C 30mm 6 F E D 2 1 H 7 8 I E E1 1 2 3 2mm 9 I E E1 2mm 1 2 3 10 5 s 1 2 11 E D D1 D1 D 30mm 13 5 G F H 12 ...

Page 4: ...ews B1 see Fig 3 5 Replace spacer C with solenoid valve D during this process pay attention to the seals D1 and the direction of flow see Fig 4 6 Fit headpart F of the transformer to the base G see Fig 5 remove protection first 7 Connect headpart F of the transformer to the electronics E see Fig 6 8 Connect solenoid valve D to electronics E see Fig 6 9 Open isolating valve H see Fig 7 10 Engage pl...

Page 5: ...tch on off pre flush factory setting switched off 1 Press the TEST button test mode is switched on 2 Press the ON AUTO button as required The indicator lamp in the sensor system of the fitting flashes 4 x short pre flush is switched on 2 x long pre flush is switched off Setting mode is quit by pressing the TEST button or automatically after 60 s Set minimum delay time factory setting 7 s 1 Press t...

Page 6: ...rease reduce detection zone using remote control special accessories 36 206 Solenoid valve defective Replace solenoid valve see Replacing solenoid valve Transformer faulty Replace transformer see Replacing transformer Electronics defective indicator lamp not flashing or permanently on Replace electronics see Replacing the top plate with electronics Water flowing continuously Solenoid valve defecti...

Page 7: ...III 19 E D F 20 E2 E E3 E4 18 F 1 2 17 G F 1 2 15 D1 D1 D 14 K 2 1 16 D E ...

Page 8: ......

Page 9: ......