background image

1

English

Application 

Operation is possible in conjunction with:
- Pressurized storage heaters
- Thermally controlled instantaneous heaters
- Hydraulically controlled instantaneous heaters  
Operation with low-pressure storage heaters 
(displacement water heaters) is 

not

 possible.

Specifications 

Max. flow      

     8.3 L/min o 2.2 gpm / 60 psi

Flow pressure   
- min.                                       

7.25 psi

- recommended                         

14.5 - 72.5 psi

- greater than 72.5 psi, fit pressure reducing valve

Max. operating pressure                      

145 psi

Test pressure                                

232 psi

Temperature    
- max. (hot water inlet)                      

176 

°

F

Scalding protection possible by fitting a handle 
rotation stop (order no. 46 308).

Water connection                                    

cold - RH

          hot - LH

Non reversible cartridge

Note:

Major pressure differences between cold and hot 
water supply should be avoided.

Installation

Flush pipes thoroughly!

Mount faucet on basin

See dimensional drawing fold-out page I.
- Place seal (A) on basin and insert faucet 

with hoses (B) through the holes of the basin,
see fig. [1].

- Screw on counter unions (C) with gasket (D) from 

below. 

- Tighten hexagon nut with a 13mm socket wrench.

Mount lift rod and pop-up drain 

- Insert the lift rod part with the knob (E) through the 

body and screw on the lower part (F), see fig. [2].

- Fit pop-up drain (28 957), see fold-out page II, 

ensure that flange of pop-up drain is sealed.

Connect faucet

For this purpose the supply hoses must be connected 
to the angle stops (or other supply points), see figs. [2] 
and [3].
The cold water supply should be connected on the 
right, the hot water supply on the left side.
Avoid cross connection. The cartridge is not 
reversible.

Open angle stops and check faucet for correct 
function,

 see fig. [4].

Lift lever 

= open (water flow)

Press lever down

= closed (off)

Move lever to right 

= cold water 

Move lever to left 

= hot water

Check connections for leakage.

Flow rate limiter

This mixer is fitted with a flow rate limiter, permitting an 
infinitely individual variable reduction in the flow rate.

The highest possible flow rate is set by the factory 
before despatch. The use of flow rate limiters in 
combination with hydraulic instantaneous water 
heaters is not recommended.

For commissioning see “Replacing the cartridge”    
point 1 to 3, fig. [5] and [6].

Maintenance

Inspect and clean all parts, replace as necessary and 
grease with special grease.

Shut off the hot and cold water supply!

I. Replacing the cartridge, 

see fig. [5].

1. Lever out plug (G).
2. Loosen set screw (H) with 3mm socket spanner

and detach lever (J).

3. Remove cap (K).
4. Remove screws (L) and detach complete 

cartridge (M).

5. Replace complete cartridge (M).

Assemble in reserve order.

Observe the correct installation position!

Make sure that the cartridge seals engage in the 
grooves on the housing. Fit screws (L) and tighten 

evenly and alternately

.

II. Unscrew and clean flow regulator (13 955),

 see 

fold-out page II.
Assemble in reverse order.

Replacement parts,

 see fold-out page II ( * = special 

accessories).

Care

Instructions for care of this faucet will be found in the 
Limited Warranty supplement.