background image

1

English

Application 

Operation is possible in conjunction with:
• Pressurized storage heaters
• Thermally controlled instantaneous heaters
• Hydraulically controlled instantaneous heaters
Operation with low-pressure storage heaters (displacement 
water heaters) is 

not

 possible.

Specifications 

• Max. flow

          

25 596

 

-

 

Spout:

 

           approx. 80 L/min or 21.1 gpm / 45 psi

25 597

 

-

 

Spout:           approx. 64 L/min or 16.9 gpm / 45 psi

 

 - Handshower:   max. 9.5 L/min or 2.5 gpm / 80 psi

• Flow pressure 

- min. 

7.25 psi

- recommended 

14.5 - 72.5 psi

- greater than 72.5 psi, fit pressure reducing valve

• Max. operating pressure

145 psi

• Test pressure 

232 psi

• Temperature

- max. (hot water inlet)

176 

°

F

- max. (handshower)

158 

°

F

• Water connection

cold on right side

hot on left side

Notes:

- Installation of backflow protection must comply with local 

codes and regulations.

- An access panel must be provided for access to diverting unit 

and pipe connections.

- Major pressure differences between cold and hot water supply 

should be avoided.

Installation

Layout dimensions to establish centers and proper clearences, 
see dimensional drawings on fold-out page I.

Before soldering: 

Prepare components.

Side valves

Screw out the headparts (A), see fold-out page II, 
fig. [1]. Fit side valves to deck, the distance from the top of the 
side valve body to deck must be 1/2", see fig. [2].

Diverter

Loosen cap (B) and detach escutcheon (C), see fig. [3].
Screw out diverter cartridge (D) and unscrew connection 
nipple (E).
Fit diverter to deck, the distance from the top of the diverter body 
to deck must be 1/2", see fig. [2].

Spout,

 see fig. [4].

Before mortar and tile is applied, wrap exposed parts with tape 
to protect threads and opening. 
Estimate height of tile level and adjust spout shank for proper fit, 
make sure that tape holds up upper washer and O-ring so that 
tile can be fitted underneath.

Connect wideset,

 see figs. [5] and [6].

Important!
Do not solder the connections between the pipes and valve 
body unless all internal parts are removed

 (parts A, B, D 

and E), see figs. [1] and [3].
The spout, side valves and diverter can now be connected with 
3/4" copper tubing.
The cold water supply should be connected on the right, the hot 
water supply on the left side.
Water must flow in the direction of the arrows cast into the body 
of the side valves and diverter.

Final Installation

Side valves

Screw headparts (A) into the body, see fig. [1].
• Valve marked with 

"L"

 (left close) on the top edge of the 

headpart (A) with blue tape should be mounted on the right 
(cold water) side.

• Valve marked with 

"R"

 (right close) on the top edge of the 

headpart (A) with red tape should be mounted on the left (hot 
water) side.

Fit extension sleeve (F), escutcheon (G) and extension 
spindle (H).

Mount handle (18 076) or lever (18 077) 

not included in the 

scope of delivery,

 

see fig. [1].

- Push on handle or lever.
- Tighten with screw (I) and insert cap (J).

Install lever (18 085) 

not included in the scope of delivery.

- Push on lever complete and screw cap (K) onto 

extension spindle (H).

Diverter,

 see fig. [3].

1. Screw in nipple (E).
2. Fit diverter cartridge (D), escutcheon (C) with cap (B). The dis-

tance from the top of the cartridge spindle to deck must be 2''. 

3. Install diverter handle (L) as shown in the attached leaflet. 

Handshower,

 see fig. [7].

1. Detach mounted coupling piece (M).
2. Screw shower hose (L) onto coupling piece (M1) and fit 

through hose guide (N) from above. 

3. Snap handshower (O) onto coupling piece (M1)
4. Connect shower hose (L) to nipple (E).

Flush pipes thoroughly!

Open cold and hot water supply and check connections for 
leakage!

Maintenance

Inspect and clean all parts, replace as necessary and grease 
with special grease (Prod. no. 18 012).

Shut off cold and hot water supply!

I. Replacing the headpart,

 see fig. [8].

1. Remove handle or lever

Handle (18 076) and lever (18 077):
- Detach cover cap (J) and screw out screw (I).
- Pull off handle or lever.
Lever (18 085):
- Unscrew cap (K) and pull off lever complete.

2. Unscrew extension spindel (H).
3. Remove escutcheon (G).
4. Unscrew extension sleeve (F).
5. Unscrew headpart (A) using a 17mm socket wrench.
6. Change complete headpart (A).

Observe the different replacement part numbers of the 
headparts,

 see fold-out page I.

Observe the correct installation position!

II. Unscrew and clean flow straightener (13 907),

 see fold-out 

page I.
Assemble in reverse order.

Replacement parts,

 see fold-out page I ( * = special 

accessories).

Care

Instructions for care of this faucet will be found in the Limited 