2
English
Maintenance
Inspect and clean all components and replace if necessary.
Shut off hot and cold water supply.
Remove battery and separate plug-in connectors,
see fold-out page II, Figs [15].
I. Cartridge,
see fold-out page III, Fig. [26].
Assemble in reverse order. When installing the cartridge,
ensure that the seals are correctly seated. Replace screws
and tighten alternately.
II. Pull out spray with non-return valve,
see fold-out page III,
Fig. [27].
Assemble in reverse order.
III. Battery,
see fold-out page II, Fig. [15].
The battery must be replaced at the latest 10 years after
putting the fitting into service.
A required change will be signaled by the indicator lamp of the
controller and by the faucet. Signaling occurs when using the
Foot control function
At low battery level, the indicator lamp flashes and the water
flow starts with three short bursts of water.
In case of an almost discharged battery, the indicator lamp
flashes and the water flow
stops
after three short bursts of
water.
In case of a discharged battery, the indicator lamp flashes and
the water will
not
flow.
Assemble in reverse order.
Insert battery with correct polarity.
IV. Solenoid valve,
see fold-out page III, Figs. [28] and [29].
Assemble in reverse order.
V. Control,
see fold-out page III, Figs. [28] to [30].
Assemble in reverse order.
VI. Check valve and filter,
see fold-out page III, Fig. [31].
Assemble in reverse order.
Replacement parts
See fold-out page IV (* = special accessories).
Care
Instructions for care of this faucet will be found in the Limited
Warranty supplement.
Disposal instructions
This category of device does
not
belong in the
domestic waste, but
must
be disposed of
separately in accordance with the relevant national
regulations.
Dispose of batteries in accordance with national
regulations.
Fault
Cause
Remedial action
Water not flowing
• Water supply interrupted
- Open shut-off valves/service valves
Water flow does not
start after unsing the
Foot control
function
• Water supply interrupted
• Filter in solenoid valve blocked
• Plug-in connector of solenoid valve without
contact
• Solenoid valve defective
• No voltage
- Battery discharged
- Plug-in connector without contact
• Sensor system not correctly adjusted to
ambient conditions
- Open shut-off valves/service valves
- Clean filter
- Attach plug-in connector
- Replace solenoid valve
- Replace battery
- Check plug-in connectors
- Increase Foot control parameters
(5 highest value...1 lowest value)
Water flowing
continuously
• Solenoid valve defective
• Sensor system not correctly adjusted to
ambient conditions
- Replace solenoid valve
- Reduce Foot control parameters
(5 highest value...1 lowest value)
Undesired water
flow
• Sensor system not correctly adjusted to
ambient conditions
• Potential equalisation not provided
• Fitting not correctly calibrated
- Reduce Foot control parameters
(5 highest value...1 lowest value)
- Provide potential equalisation, see section
Connecting the faucet
- Remove battery and re-insert it. Check again after
the indicator lamp goes out
Flow rate too low
• Mousseur dirty
• Filter in solenoid valve dirty
• Shut-off valves, service valves not fully open
- Clean or replace mousseur
- Clean filter
- Fully open shut-off valves, service valves and
check supply lines
Summary of Contents for K7 30 314
Page 3: ...II 16mm 19mm 11 19mm 22mm 10 12 17 14 15 16 13...
Page 11: ...II IV...