Function F6 - Assign points of discharge to the buttons of the digital diverter (not for 36 294
)
,
see fold-out page IV, Fig. [21].
Maintenance
Inspect and clean all components and replace if necessary.
Close isolating valves. Open all occupied outlets with digital
controller/diverter. Disconnect voltage supply.
I. Change digital controller/diverter batteries,
see fold-out page IV,
Fig. [23] and fold-out page III, Figs. [11] to [15].
Insert batteries with correct polarity.
II. Servo motor and thermostatic compact cartridge,
see fold-out
page IV, Fig. [24] to [26].
Assemble in reverse order.
Observe the correct installation position of the thermostatic compact
cartridge,
see detail Fig. [25].
1.Connect plug connector servo motor, see Fig. [24].
2.Establish voltage supply. The servo motor calibrates and the buttons of
the digital controller/diverter are now inoperative for 3 minutes. Finally
the cams must be positioned one above the other, see Fig. [26].
If cams are not positioned one above the other, disconnect voltage
supply and than reconnect again.
3.Open isolating valves and start water flow at the digital controller.
4.Turn the adjusting nut (C) until the water temperature reaches 100 °F,
see Figs. [22] and [24].
5.Put servo motor to thermostatic compact cartridge.
III. Non-return valve,
see fold-out page IV, Fig. [27].
Assemble in reverse order.
IV. Solenoid valve,
see fold-out page IV, Fig. [28].
Assemble in reverse order.
Service
In the event of problems with installation, please switch off the voltage
supply and consult a specialist installer or the GROHE Service Hotline via
email at
.
Replacement parts
See fold-out page I (* = special accessories).
Disposal instructions
Button
Description
Visualization
Start the function menu
- Select the function by simultaneously pressing and holding the
- / +
buttons.
-
F6
Function
select by turning the ring.
•
Start F6
- Assign points of discharge to the buttons of the digital diverter.
=> Confirm by simultaneously pressing the
- / +
buttons.
- Press one of the digital diverter
buttons 1, 2 or
3
.
- Change point of discharge by turning the digital controler ring. The buttons are
factory assigned to the points of discharge
1
-
2
-
3
.
By further turning the point of discharge may be closed. A maximum of two point of
discharge could be stored as closed.
- Press the next digital diverter button.
=>
Pressing the
- / +
buttons simultaneously saves the selection and exits the menu.
Abort
the function menu by pressing and holding
Start/Stopp
button or
after 3 minutes without triggering.
Illuminated ring flashes red 1x.
Illuminated ring flashes red 6x.
Illuminated ring flashes green 1x.
Water flow starts and the segment of the selected
button flashes blue 1x.
Water flow changes to the selected point of discharge.
Water flow starts and the segment of the selected
button flashes blue 1x.
Illuminated ring flashes green 3x.
Illuminated ring flashes violet 1x.
This category of device does
not
belong in the domestic waste,
but
must
be disposed of separately in accordance with the
relevant local national regulations.
Dispose of batteries in accordance with national regulations.
Fault
Cause
Remedy
Water does not flow
• Water supply interrupted
• Plug-in connector without contact or no voltage
supply
• Solenoid valve defective
- Open shut-off valves, isolating valves
- Attach plug-in connectors and connect voltage supply
- Replace solenoid valve, see section
Maintenance
Flow rate too low
• Functional unit not adapted to local conditions
- Adapt functional unit to local conditions, see
Function
F2
-
Setting
mode
Water too cold/hot
• Functional unit not adapted to local conditions
- Adapt functional unit to local conditions, see
Function
F2
-
Setting
mode
No function
• Digital controller not ready or registered
- Register digital controller/diverter, see
Function
F3 - Register/de-
register
• Digital controller/diverter out of range
• Radio interference
• Obstacle in transmission path
- Check transceiver or change position
- Deactivate potential source of interference and check function again
=> If positive reconfigure the interference source (eg wireless router)
- Rectify the fault see section
Operating conditions
•
1x:
Batteries digital controller/diverter almost
empty
•
3x:
Temperature too high
•
5x:
Calibration servo motor not completed
- Check installation or replace unit battery, see section
Maintenance
- Wait until feeler gauge is cooling down
- Calibrate functional unit, see section
F2 - Setting mode
- Wait 3 minutes, switch off the voltage supply and reconnect
• Software malfunction
- Switch off the voltage supply and consult a specialist installer
or the GROHE Service Hotline
• Hard- or software malfunction
- Switch off the voltage supply and consult a specialist installer
or return the product to GROHE
Segment flashes 1x
white
Segment flashes
green
Segment flashes 1x
yellow
Segment flashes 1x
red
Please pass these instructions on to the end user of the fitting.