Safety notes
Prevent danger resulting from damaged voltage
supply cables.
If damaged, the voltage supply cable must be
replaced by the manufacturer or his customer service
department or an equally qualified person.
• Installation is only possible in frost-free rooms.
• The plug-in voltage supply is only suitable for indoor use.
• The plug-in connectors must
not
be directly or indirectly
sprayed with water when cleaning.
• The voltage supply must be separately switchable.
• Use
only genuine replacement parts and accessories
.
The use of other parts will result in voiding of the warranty
and the CE identification, and could lead to injuries.
Technical data
• Max. flow:
0.8 L/cycle or 0.2 gpc / 0.41 MPa (60 psi)
• Flow pressure:
- min.
0.05 MPa (7.25 psi)
- recommended
0.1 - 0.5 MPa (14.5 - 72.5 psi)
• Operating pressure:
max. 1 MPa (145 psi)
• Test pressure:
1.6 MPa (232 psi)
• Hot water supply temperature:
max. 158 °F
Recommended (energy economy):
140 °F
Thermal disinfection possible.
Fitting with battery:
• Voltage supply:
6V lithium battery type CR-P2
Fitting with switched-mode power supply (42 464):
• Voltage supply:
100-240 V AC 50-60 Hz/6.75 V DC
• Power consumption:
2.4 W
• Automatic safety shut-off
(6 - 420 s adjustable):
11 s
• Run-on time (0 - 19 s adjustable):
1 s
• Reception range according to Kodak Gray Card,
grey side, 8x10", landscape (adjustable):
approx. 5“
• Type of fitting protection:
IP 59K
Electrical test data
• Software class
A
• Contamination class
2
• Rated surge voltage
2500 V
• Temperature of ball impact test
100 °C
The test for electromagnetic compatibility (interference emission
test) was performed at the rated voltage and rated current.
If static pressures exceed 0.5 MPa (72.5 psi), a pressure-
reducing valve must be installed.
Major pressure differences between cold and hot water supply
should be avoided.
Installation
, see fold-out page I.
Flush piping system prior and after installation of
fitting thoroughly!
Open cold and hot water supply and check
connections for leakage.
Setting temperature limiter,
see fold-out page II.
Operation,
see technical product information, 99.0438.xxx.
Maintenance
, see fold-out page II.
• Shut off hot and cold water supply.
• Disconnect voltage supply.
• Inspect and clean all components and replace if
necessary.
Replacement parts
see fold-out page I (* = special accessories)
,
Care
Instructions for care of this faucet will be found in the Limited
Warranty supplement.
Fault / Cause / Remedy
Fault
Cause
Remedy
Water not flowing
• Filter in solenoid valve blocked
• Solenoid valve defective
• Plug-in connector without contact
• No voltage
- Battery discharged
(indicator lamp lights up continuously)
- Power supply unit defective
- Clean filter
- Replace solenoid valve
- Check plug-in connector
- Replace battery
- Replace power supply unit
Undesired water
flow
• Sensor system detection zone set too high
for local conditions
• Automatic flushing activated
• Solenoid valve defective
- Reduce range using remote control (special
accessory, prod. no.: 36 407)
- Wait 1 - 10 minutes
- Replace solenoid valve
Flow rate too low
• Mousseur dirty
• Filter in solenoid valve dirty
• Filters in connection hose dirty
- Clean or replace mousseur
- Clean filter
- Clean or replace filters