background image

1

English

Application

Operation is possible in conjunction with:
• Pressurized storage heaters

Operation is 

not

 possible with:

• Low-pressure storage heaters (displacement water heaters)

Specifications

• Max. flow:

           6.6 L/min or 1.75 gpm/60 psi

• Flow pressure   

- min.                                       

7.25 psi

- recommended                         

14.5 - 72.5 psi

- greater than 72.5 psi, fit pressure reducing valve

• Max. operating pressure                      

145 psi

• Test pressure                                

232 psi

• Temperature    

- max. (hot water inlet)                      

176 

°

F

• Water connection:                                   cold - RH    hot - LH
• Deck thickness max.

2 3/8"

• Non reversible cartridge

Notes:

- Major pressure differences between cold and hot water 

supply should be avoided.

- To be installed according to local codes and regulations.
- This faucet is not intended for the use with portable 

appliances.

Installation

Flush piping system prior and after installation of faucet 
thoroughly! 

Prepare sink faucet

Refer to the dimensional drawing on fold-out page I.

Fit escutcheon (A) with mounting set (B), 

see fold-out 

page I, Fig. [1].

Mount sink faucet, 

see fold-out page III, Figs. [2] and [3].

1. Fit flange and O-Ring (C).
2. Insert faucet into sink. Feed the connection hoses 

separately through the sink.

3. Fit brace (D), if necessary.
4. Tighten threaded flange (E) against washer (E1) and (D1).
5. Tighten the screws (F).

Note:

If brace (D) is omitted, deck thickness can be increased 
by 9/16" to a total of 2 3/8".

Connect sink faucet,

 see Figs. [2] and [3].

- Cold water connection (marked blue)

= right

- Hot water connection (marked red)

= left

Avoid cross connection. The cartridge is not reversible.

Connect hose, 

see Fig. [4].

1. Screw hose (K) with washer (K1) onto the nipple (L) of the 

faucet.

2. Attach weight (J) to shower hose.

Open cold and hot water supply and check connections 
for leakage!

Operation

Lever,

 see fold-out page III, Fig. [5]. 

Spray,

 see Fig. [6].

Turning off the faucet automatically diverts the water flow from 
spray to aerator.

Flow rate limiter

This faucet is fitted out with a flow rate limiter, permitting an 
infinitely individual variable reduction of the flow rate. The 
highest possible flow rate is set by the plant before despatch.

The use of flow rate limiters in combination with hydraulic 
instantaneous water heaters is not recommended.

To activate see “Replacing the cartridge” point 1 to 3, 
Figs. [7] and [8].

Maintenance

Inspect and clean all parts, replace as necessary and grease 
with special grease.

Shut off cold and hot water supply!

I. Replacing the cartridge,

 see fold-out page III, Fig. [7].

1. Lever out plug (N).
2. Remove fixing screw (O) and pull off lever (M).
3. Pull off the cap (R).
4. Turn out screwing (S) with wrench 30mm.
5. Change the complete cartridge (T).
Assemble in reverse order.

Observe the correct installation position!

Make sure that the cartridge seals engage in the grooves and 
the locating pins at the base of the cartridge slot into the 
apertures on the housing. 

II. Check valve,

 see fold-out page II 

(48 224)

 and III, Fig. [9].

- Unscrew spray (I) and remove filter (U) and check valve (V), 

see Fig. [9].

III. Strainer and rose,

 see fold-out page III, Fig. [9].

1. Pull out ring (W) and unscrew rose (X) by using wrench (Y).
2. Clean strainer (Z) and rose (X).
Thanks to the SpeedClean nozzles, which must be regularly 
cleaned, limescale deposits on the rose can be removed by 
simply rubbing with the fingers.
The function of the SpeedClean nozzles is guaranteed for a 
period of five years.
Assemble in reverse order.

Replacement parts,

 see fold-out page II ( * = special 

accessories).

Care

Instructions for care of this faucet will be found in the Limited 
Warranty supplement.

Summary of Contents for Elberon 30 211

Page 1: ...English 1 Français 2 Español 3 Design Engineering GROHE Germany Elberon Elberon 99 0174 031 ÄM 229346 12 13 30 211 ...

Page 2: ...I S v p remettre cette instruction à l utilisateur de la robinetterie Entregue estas instrucciones al usario final de la grifería Please pass these instructions on to the end user of the fitting ...

Page 3: ...II ...

Page 4: ...hot water supply and check connections for leakage Operation Lever see fold out page III Fig 5 Spray see Fig 6 Turning off the faucet automatically diverts the water flow from spray to aerator Flow rate limiter This faucet is fitted out with a flow rate limiter permitting an infinitely individual variable reduction of the flow rate The highest possible flow rate is set by the plant before despatch...

Page 5: ... au niveau du flexible de douche Ouvrir l arrivée d eau froide et d eau chaude et vérifier l étanchéité des raccords Utilisation Levier voir volet III fig 5 Douchette voir fig 6 La fermeture de la robinetterie entraîne automatiquement une commutation du jet de la douchette à celui du mousseur Limiteur de débit Ce mitigeur est équipé d un limiteur de débit Celui ci permet une limitation individuali...

Page 6: ...del agua caliente y comprobar la estanqueidad de las conexiones Manejo Palanca véase la página desplegable III fig 5 Teleducha véase la fig 6 Al cerrar el monomando se pasa automáticamente de chorro de ducha a chorro de mousseur Limitador de caudal Este monomando está equipado con una limitación de caudal Gracias a ello es posible una limitación individual sin escalonamientos del caudal El ajuste ...

Page 7: ...III 3 D E1 C 16mm E F D1 2 2 4 K1 K L J 15mm 18mm 9 1 2 U V I Z X Y W 6 8 2 5mm 5 7 M O R T S 30mm N 1 A B 27mm ...

Page 8: ......

Page 9: ......

Page 10: ...30 info grohe co jp KZ 7 727 311 07 39 info cac grohe com LT 372 6616354 grohe grohe ee LV 372 6616354 grohe grohe ee MAL 1 800 80 6570 info singapore grohe com N 47 22 072070 grohe grohe no NL 31 79 3680133 vragen nl grohe com NZ 09 373 4324 P 351 234 529620 commercial pt grohe com PL 48 22 5432640 bLuro grohe com pl RI 62 21 2358 4751 info singapore grohe com RO 40 21 2125050 info ro grohe com R...

Reviews: