1
English
Application
Operation is possible in conjunction with:
- Pressurized storage heaters
- Thermally controlled instantaneous heaters
- Hydraulically controlled instantaneous heaters
Operation with low-pressure storage heaters
(displacement water heaters) is not possible.
Specifications
•
Max. flow
8.3 L/min or 2.2 gpm/60 psi
•
Flow pressure
- min.
7.25 psi
- recommended
14.5 - 72.5 psi
- greater than 72.5 psi, fit pressure
reducing valve
•
Max. operating pressure
145 psi
•
Test pressure
232 psi
•
Temperature
- max. (hot water inlet)
176
°
F
Scalding protection possible by fitting a handle
rotation stop (order no. 46 308).
•
Water connection
hot - LH
cold - RH
•
Non reversible cartridge
Note
Major pressure differences between hot and cold
water supply should be avoided.
Installation
Flush pipes thoroughly.
Mount faucet on basin
See dimensional drawing fold-out page I.
For installation you require only a 13mm (1/2’’) socket
wrench, see fold-out page III, fig. [1].
Connect faucet
For this purpose the supply tubes must be connected
to the angle stops (or other supply points), see fig. [1].
The hot water supply should be connected on the left,
the cold water supply on the right side.
Avoid cross connection. The cartridge is not
reversible.
Fit pop-up drain (28 957), see fold-out page II, ensure
that flange of pop-up drain is sealed.
Open angle stops and check faucet for correct
function, see fig. [2].
Lift lever
= open (water flow)
Press lever down
= closed (off)
Move lever to right
= cold water
Move lever to left
= hot water
Check connections for leakage.
Flow rate limiter
This mixer is fitted with a flow rate limiter, permitting an
infinitely individual variable reduction in the flow rate.
The highest possible flow rate is set by the factory
before despatch.
The use of flow rate limiters in combination with
hydraulic instantaneous water heaters is not
recommended.
For commissioning see “replacing the cartridge”
point 1 to 3, fig. [3] and [4].
Maintenance
Inspect and clean all parts, replace as necessary and
grease with special grease (order no. 18 012).
I. Replacing the cartridge, see fig. [3].
1. Remove cover cap (A).
2. Remove screw (B) and pull off lever (C).
3. Remove cap (D).
4. Remove screws (F) and detach complete
cartridge (G).
5. Change either complete cartridge (G) or seals (G1).
Assemble in reserve order.
Make sure that the cartridge seals (G1) engage in the
grooves on the housing. Fit screws (F) and tighten
evenly and alternately.
II. Flow regulator, see fold-out page II.
Unscrew and clean flow regulator (13 955).
Assemble in reverse order.
Replacement parts, see fold-out page II ( * = special
accessories).
Care
Instructions for care of this single lever faucet will be
found in the Limited Warranty supplement.
954852.book : i95485us.fm Seite 1 Donnerstag, September 20, 2001 8:49 AM
Summary of Contents for Chiara 33148
Page 3: ...II 954852 book t95485 fm Seite 3 Donnerstag September 20 2001 8 49 AM ...
Page 8: ...954852 book notizen fm Seite 5 Donnerstag September 20 2001 8 49 AM ...
Page 9: ...954852 book notizen1 fm Seite 6 Donnerstag September 20 2001 8 49 AM ...
Page 10: ...954852 book adresus fm Seite 7 Donnerstag September 20 2001 8 49 AM ...