Application

Pressure Balancing Valves are designed for use with 
hot water supplied from pressurized storage heaters 
and offer the highest temperature accuracy when used 
in this way. 

Pressure Balancing Valves cannot be used in 
conjunction with low-pressure storage heaters 
(displacement water heaters).

Specifications

Concealed single handle pressure balancing tub 
and shower valve

Integral service stops (35 210 / 35 214)

Integral check valves prevents cross flow

Pressure balanced diaphragm cartridge automati-
cally adjusts to inlet pressure fluctuations. 
Cartridge restricts hot water supply should the cold 
water pressure fail - to prevent scalding.

Flow pressure
- min. 

20 psi

-  recommended 

20 - 72.5 psi

-  greater than 72.5 psi, fit pressure reducing valve

Max. operating pressure 

145 psi

Max. test pressure 

500 psi

Flow rate:
- Outlet  

   

   13.5 L/min or 3.5 gpm/20 psi

                     20 L/min or 5.2 gpm/45 psi
                   30.5 L/min or 8 gpm/100 psi

- Shower  

   

       13 L/min or 3.4 gpm/20 psi

                        19 L/min or 5 gpm/45 psi
                   29 L/min or 7.6 gpm/100 psi

Temperature
- max. (hot water inlet) 

176 

°

F

- maximum temperature is reached when the 

handle is rotated 270

°

 in a counterclockwise 

direction. 
The handle rotation stop may be used to limit the 
maximum temperature.

Back to back installation possible by reversing the 
pressure balancing cartridge

Water connection 

hot - LH

 cold 

RH

Installation

Final installation

   1. Remove the two screws (A1) from the fitting 

template (A), then remove the template, 
see fold-out page I, fig. [1].

   2. Make sure the water supply is turned on at the 

service stop valves (B). Stop valves must be in 
fully open position.

   3. Turn the valve stem (C) clockwise to OFF 

position, see fig. [2].

   4. The adjustable hot water limit stop (D) is factory 

set at neutral position to give maximum outlet 
temperature. 
Please refer to chapter "Maximum hot water 
limit setting"
 on page 2 for limiting maximum 
outlet temperature.

   5. Install lever adapter (E) onto the valve stem (C), 

by placing the lever stop pin (E1) on top of the 
"Arrow" (

), then tighten with screw (G).

   6. Push cap (H) with drain hole facing down onto  

the plastic guide (J) by gently pressing the
slotted section (J1) on the plastic guide.

   7. Slide the escutcheon (K) over the cap (H), 

see fig. [3].

   8. Place snap inserts (L) and tighten escutcheon 

with screws (L1).
Do not use excessive force to tighten the screws.

   9. Cover the screws with cover caps (L2).

 10. Remove the cover cap (M) from the lever 

handle (N), see fig. [4].

 11. Position the handle with lever facing down over 

the lever adapter (E) and tighten with screw (O). 

 12. Replace the cover cap (M).

The pressure balancing valve is now ready 
for use.

Caution!

Do not lift the lever on the handle to operate this 
valve. This pressure balancing valve opens  from 
cold to hot by turning the lever counterclockwise,
 
see fig. [5]. 

If the pressure balancing valve is installed too 
deep, 
the fitting depth can be increased by 1" with an 
extension set, Part No. 47 344, see fold-out page II.

954800.book : I95480us.fm  Seite 1  Dienstag, März 16, 1999  1:46 PM

Summary of Contents for Chiara 19 713

Page 1: ...página 3 English Français Español page 1 page 2 19 713 95 480 031 ÄM 21 377 03 99 Chiara página 5 English Français Español page 1 page 3 954800 book t95480 fm Seite 1 Dienstag März 16 1999 1 46 PM ...

Page 2: ...re cette instruction à l utilisateur de la robinetterie Sirvanse pasar ese instrucción al utilizador de la grifería Please pass these instructions on to the end user of the fitting 6 D 2 C E G H E1 D J J1 kl954800 fm Seite 1 Montag März 15 1999 1 20 PM ...

Page 3: ...II 35 210 35 214 35 215 35 216 19 713 kl954800 fm Seite 2 Montag März 15 1999 1 20 PM ...

Page 4: ...he two screws A1 from the fitting template A then remove the template see fold out page I fig 1 2 Make sure the water supply is turned on at the service stop valves B Stop valves must be in fully open position 3 Turn the valve stem C clockwise to OFF position see fig 2 4 The adjustable hot water limit stop D is factory set at neutral position to give maximum outlet temperature Please refer to chap...

Page 5: ...ved from the valve casing during the system shut off for winterizing Maintenance Pressure balancing cartridge see figs 10 to 12 1 Pull off cover cap M loosen screw O and detach lever N see fig 10 2 Detach cover caps L2 loosen screws L1 and remove escutcheon K 3 Shut off hot and cold water stops B see fig 11 4 Pull off cap H see fig 12 5 Loosen screws J2 and detach plastic guide J with sleeve 6 Det...

Page 6: ...montage A puis retirer celui ci voir volet I fig 1 2 S assurer que l admission d eau est en service aux robinets d arrêt B Ceux ci doivent être entièrement ouverts 3 Tourner la tige de robinet C sur la position OFF dans le sens des aiguilles d une montre voir fig 2 4 La butée réglable pour l eau chaude D est réglée en usine en position neutre pour obtenir une température de sortie maximum Se référ...

Page 7: ...s de robinet pendant la coupure du système pour l hivernisation Maintenance Cartouche d équilibrage de pression voir figs 10 à 12 1 Retirer l enjoliveur M desserrer la vis O et enlever la manette N voir fig 10 2 Retirer les enjoliveurs L2 desserrer les vis L1 et enlever la rosace K 3 Couper l eau chaude et l eau froide B voir fig 11 4 Enlever le capuchon H voir fig 12 5 Desserrer les vis J2 et ret...

Page 8: ...úrese de que las llaves de paso B estén abiertas Las llaves de paso tienen que estar completamente abiertas 3 Gire el vástago C de la válvula en el sentido de los punteros del reloj hacia la posición OFF ver fig 2 4 El tope final del agua caliente ajustable D se suministra de fábrica en posición neutral de modo de permitir una temperatura de salida máxima Le rogamos consultar el capítulo Fijación ...

Page 9: ...a sacar de la carcasa de la válvula el Cartucho compensador de presión integrado Mantenimiento Cartucho compensador de presión ver figs 10 a 12 1 Retire la tapa de revestimiento M suelte el tor nillo O y remueva la palanca N ver fig 10 2 Remueva las caperuzas de revestimiento L2 suelte los tornillos L1 y remueva el rosetón K 3 Cierre las llaves de paso de agua caliente y agua fría B ver fig 11 4 R...

Page 10: ...III 7 D 10 K L N O M L1 L2 9 D1 8 E C E1 12 Z S R1 R J2 P J H S1 11 B B 954800 book kr95480 fm Seite 7 Dienstag März 16 1999 1 46 PM ...

Page 11: ...954800 book notizen fm Seite 8 Dienstag März 16 1999 1 46 PM ...

Page 12: ...l Services Phone 630 582 7711 Fax 630 582 7722 Grohe Canada Inc 1230 Lakeshore Road East Mississauga Ontario Canada L5E 1E9 Technical Services Services Techniques Phone Tél 905 271 2929 Fax Télécopieur 905 271 9494 954800 book adresus fm Seite 9 Dienstag März 16 1999 1 46 PM ...

Reviews: